ceph: improve structure and existing screenshot placements
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
This commit is contained in:
parent
cb04e768a7
commit
513e2f5752
87
pveceph.adoc
87
pveceph.adoc
@ -125,8 +125,9 @@ In general SSDs will provide more IOPs than spinning disks. With this in mind,
|
||||
in addition to the higher cost, it may make sense to implement a
|
||||
xref:pve_ceph_device_classes[class based] separation of pools. Another way to
|
||||
speed up OSDs is to use a faster disk as a journal or
|
||||
DB/**W**rite-**A**head-**L**og device, see xref:pve_ceph_osds[creating Ceph
|
||||
OSDs]. If a faster disk is used for multiple OSDs, a proper balance between OSD
|
||||
DB/**W**rite-**A**head-**L**og device, see
|
||||
xref:pve_ceph_osds[creating Ceph OSDs].
|
||||
If a faster disk is used for multiple OSDs, a proper balance between OSD
|
||||
and WAL / DB (or journal) disk must be selected, otherwise the faster disk
|
||||
becomes the bottleneck for all linked OSDs.
|
||||
|
||||
@ -157,6 +158,9 @@ You should test your setup and monitor health and performance continuously.
|
||||
Initial Ceph Installation & Configuration
|
||||
-----------------------------------------
|
||||
|
||||
Using the Web-based Wizard
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
[thumbnail="screenshot/gui-node-ceph-install.png"]
|
||||
|
||||
With {pve} you have the benefit of an easy to use installation wizard
|
||||
@ -165,11 +169,16 @@ section in the menu tree. If Ceph is not already installed, you will see a
|
||||
prompt offering to do so.
|
||||
|
||||
The wizard is divided into multiple sections, where each needs to
|
||||
finish successfully, in order to use Ceph. After starting the installation,
|
||||
the wizard will download and install all the required packages from {pve}'s Ceph
|
||||
repository.
|
||||
finish successfully, in order to use Ceph.
|
||||
|
||||
After finishing the first step, you will need to create a configuration.
|
||||
First you need to chose which Ceph version you want to install. Prefer the one
|
||||
from your other nodes, or the newest if this is the first node you install
|
||||
Ceph.
|
||||
|
||||
After starting the installation, the wizard will download and install all the
|
||||
required packages from {pve}'s Ceph repository.
|
||||
|
||||
After finishing the installation step, you will need to create a configuration.
|
||||
This step is only needed once per cluster, as this configuration is distributed
|
||||
automatically to all remaining cluster members through {pve}'s clustered
|
||||
xref:chapter_pmxcfs[configuration file system (pmxcfs)].
|
||||
@ -208,10 +217,11 @@ more, such as xref:pveceph_fs[CephFS], which is a helpful addition to your
|
||||
new Ceph cluster.
|
||||
|
||||
[[pve_ceph_install]]
|
||||
Installation of Ceph Packages
|
||||
-----------------------------
|
||||
Use the {pve} Ceph installation wizard (recommended) or run the following
|
||||
command on each node:
|
||||
CLI Installation of Ceph Packages
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Alternatively to the the recommended {pve} Ceph installation wizard available
|
||||
in the web-interface, you can use the following CLI command on each node:
|
||||
|
||||
[source,bash]
|
||||
----
|
||||
@ -222,10 +232,8 @@ This sets up an `apt` package repository in
|
||||
`/etc/apt/sources.list.d/ceph.list` and installs the required software.
|
||||
|
||||
|
||||
Create initial Ceph configuration
|
||||
---------------------------------
|
||||
|
||||
[thumbnail="screenshot/gui-ceph-config.png"]
|
||||
Initial Ceph configuration via CLI
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Use the {pve} Ceph installation wizard (recommended) or run the
|
||||
following command on one node:
|
||||
@ -246,6 +254,9 @@ configuration file.
|
||||
[[pve_ceph_monitors]]
|
||||
Ceph Monitor
|
||||
-----------
|
||||
|
||||
[thumbnail="screenshot/gui-ceph-monitor.png"]
|
||||
|
||||
The Ceph Monitor (MON)
|
||||
footnote:[Ceph Monitor {cephdocs-url}/start/intro/]
|
||||
maintains a master copy of the cluster map. For high availability, you need at
|
||||
@ -254,13 +265,10 @@ used the installation wizard. You won't need more than 3 monitors, as long
|
||||
as your cluster is small to medium-sized. Only really large clusters will
|
||||
require more than this.
|
||||
|
||||
|
||||
[[pveceph_create_mon]]
|
||||
Create Monitors
|
||||
~~~~~~~~~~~~~~~
|
||||
|
||||
[thumbnail="screenshot/gui-ceph-monitor.png"]
|
||||
|
||||
On each node where you want to place a monitor (three monitors are recommended),
|
||||
create one by using the 'Ceph -> Monitor' tab in the GUI or run:
|
||||
|
||||
@ -335,17 +343,16 @@ telemetry and more.
|
||||
[[pve_ceph_osds]]
|
||||
Ceph OSDs
|
||||
---------
|
||||
|
||||
[thumbnail="screenshot/gui-ceph-osd-status.png"]
|
||||
|
||||
Ceph **O**bject **S**torage **D**aemons store objects for Ceph over the
|
||||
network. It is recommended to use one OSD per physical disk.
|
||||
|
||||
NOTE: By default an object is 4 MiB in size.
|
||||
|
||||
[[pve_ceph_osd_create]]
|
||||
Create OSDs
|
||||
~~~~~~~~~~~
|
||||
|
||||
[thumbnail="screenshot/gui-ceph-osd-status.png"]
|
||||
|
||||
You can create an OSD either via the {pve} web-interface or via the CLI using
|
||||
`pveceph`. For example:
|
||||
|
||||
@ -406,7 +413,6 @@ NOTE: The DB stores BlueStore’s internal metadata, and the WAL is BlueStore’
|
||||
internal journal or write-ahead log. It is recommended to use a fast SSD or
|
||||
NVRAM for better performance.
|
||||
|
||||
|
||||
.Ceph Filestore
|
||||
|
||||
Before Ceph Luminous, Filestore was used as the default storage type for Ceph OSDs.
|
||||
@ -462,8 +468,8 @@ known as **P**lacement **G**roups (`PG`, `pg_num`).
|
||||
Create and Edit Pools
|
||||
~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
You can create pools from the command line or the web-interface of any {pve}
|
||||
host under **Ceph -> Pools**.
|
||||
You can create and edit pools from the command line or the web-interface of any
|
||||
{pve} host under **Ceph -> Pools**.
|
||||
|
||||
[thumbnail="screenshot/gui-ceph-pools.png"]
|
||||
|
||||
@ -475,16 +481,18 @@ WARNING: **Do not set a min_size of 1**. A replicated pool with min_size of 1
|
||||
allows I/O on an object when it has only 1 replica, which could lead to data
|
||||
loss, incomplete PGs or unfound objects.
|
||||
|
||||
It is advised that you calculate the PG number based on your setup. You can
|
||||
find the formula and the PG calculator footnote:[PG calculator
|
||||
https://ceph.com/pgcalc/] online. From Ceph Nautilus onward, you can change the
|
||||
number of PGs footnoteref:[placement_groups,Placement Groups
|
||||
It is advised that you either enable the PG-Autoscaler or calculate the PG
|
||||
number based on your setup. You can find the formula and the PG calculator
|
||||
footnote:[PG calculator https://ceph.com/pgcalc/] online. From Ceph Nautilus
|
||||
onward, you can change the number of PGs
|
||||
footnoteref:[placement_groups,Placement Groups
|
||||
{cephdocs-url}/rados/operations/placement-groups/] after the setup.
|
||||
|
||||
In addition to manual adjustment, the PG autoscaler
|
||||
footnoteref:[autoscaler,Automated Scaling
|
||||
The PG autoscaler footnoteref:[autoscaler,Automated Scaling
|
||||
{cephdocs-url}/rados/operations/placement-groups/#automated-scaling] can
|
||||
automatically scale the PG count for a pool in the background.
|
||||
automatically scale the PG count for a pool in the background. Setting the
|
||||
`Target Size` or `Target Ratio` advanced parameters helps the PG-Autoscaler to
|
||||
make better decisions.
|
||||
|
||||
.Example for creating a pool over the CLI
|
||||
[source,bash]
|
||||
@ -496,7 +504,12 @@ TIP: If you would also like to automatically define a storage for your
|
||||
pool, keep the `Add as Storage' checkbox checked in the web-interface, or use the
|
||||
command line option '--add_storages' at pool creation.
|
||||
|
||||
.Base Options
|
||||
Pool Options
|
||||
^^^^^^^^^^^^
|
||||
|
||||
The following options are available on pool creation, and partially also when
|
||||
editing a pool.
|
||||
|
||||
Name:: The name of the pool. This must be unique and can't be changed afterwards.
|
||||
Size:: The number of replicas per object. Ceph always tries to have this many
|
||||
copies of an object. Default: `3`.
|
||||
@ -515,7 +528,7 @@ xref:pve_ceph_device_classes[Ceph CRUSH & device classes] for information on
|
||||
device-based rules.
|
||||
# of PGs:: The number of placement groups footnoteref:[placement_groups] that
|
||||
the pool should have at the beginning. Default: `128`.
|
||||
Target Size Ratio:: The ratio of data that is expected in the pool. The PG
|
||||
Target Ratio:: The ratio of data that is expected in the pool. The PG
|
||||
autoscaler uses the ratio relative to other ratio sets. It takes precedence
|
||||
over the `target size` if both are set.
|
||||
Target Size:: The estimated amount of data expected in the pool. The PG
|
||||
@ -555,6 +568,7 @@ PG Autoscaler
|
||||
|
||||
The PG autoscaler allows the cluster to consider the amount of (expected) data
|
||||
stored in each pool and to choose the appropriate pg_num values automatically.
|
||||
It is available since Ceph Nautilus.
|
||||
|
||||
You may need to activate the PG autoscaler module before adjustments can take
|
||||
effect.
|
||||
@ -589,6 +603,9 @@ Nautilus: PG merging and autotuning].
|
||||
[[pve_ceph_device_classes]]
|
||||
Ceph CRUSH & device classes
|
||||
---------------------------
|
||||
|
||||
[thumbnail="screenshot/gui-ceph-config.png"]
|
||||
|
||||
The footnote:[CRUSH
|
||||
https://ceph.com/wp-content/uploads/2016/08/weil-crush-sc06.pdf] (**C**ontrolled
|
||||
**R**eplication **U**nder **S**calable **H**ashing) algorithm is at the
|
||||
@ -673,8 +690,8 @@ Ceph Client
|
||||
|
||||
Following the setup from the previous sections, you can configure {pve} to use
|
||||
such pools to store VM and Container images. Simply use the GUI to add a new
|
||||
`RBD` storage (see section xref:ceph_rados_block_devices[Ceph RADOS Block
|
||||
Devices (RBD)]).
|
||||
`RBD` storage (see section
|
||||
xref:ceph_rados_block_devices[Ceph RADOS Block Devices (RBD)]).
|
||||
|
||||
You also need to copy the keyring to a predefined location for an external Ceph
|
||||
cluster. If Ceph is installed on the Proxmox nodes itself, then this will be
|
||||
|
Loading…