The Proxmox Cluster file system (``pmxcfs'') is a database-driven file
|
|
system for storing configuration files, replicated in real time to all
|
|
cluster nodes using `corosync`. We use this to store all {PVE} related
|
|
configuration files.
|
|
|
|
Although the file system stores all data inside a persistent database on disk,
|
|
a copy of the data resides in RAM. This imposes restrictions on the maximum
|
|
size, which is currently 128 MiB. This is still enough to store the
|
|
configuration of several thousand virtual machines.
|
|
|
|
This system provides the following advantages:
|
|
|
|
* Seamless replication of all configuration to all nodes in real time
|
|
* Provides strong consistency checks to avoid duplicate VM IDs
|
|
* Read-only when a node loses quorum
|
|
* Automatic updates of the corosync cluster configuration to all nodes
|
|
* Includes a distributed locking mechanism
|
|
|
|
|
|
POSIX Compatibility
|
|
-------------------
|
|
|
|
The file system is based on FUSE, so the behavior is POSIX like. But
|
|
some feature are simply not implemented, because we do not need them:
|
|
|
|
* You can just generate normal files and directories, but no symbolic
|
|
links, ...
|
|
|
|
* You can't rename non-empty directories (because this makes it easier
|
|
to guarantee that VMIDs are unique).
|
|
|
|
* You can't change file permissions (permissions are based on paths)
|
|
|
|
* `O_EXCL` creates were not atomic (like old NFS)
|
|
|
|
* `O_TRUNC` creates are not atomic (FUSE restriction)
|
|
|
|
|
|
File Access Rights
|
|
------------------
|
|
|
|
All files and directories are owned by user `root` and have group
|
|
`www-data`. Only root has write permissions, but group `www-data` can
|
|
read most files. Files below the following paths are only accessible by root:
|
|
|
|
/etc/pve/priv/
|
|
/etc/pve/nodes/${NAME}/priv/
|
|
|
|
|
|
Technology
|
|
----------
|
|
|
|
We use the https://www.corosync.org[Corosync Cluster Engine] for
|
|
cluster communication, and https://www.sqlite.org[SQlite] for the
|
|
database file. The file system is implemented in user space using
|
|
https://github.com/libfuse/libfuse[FUSE].
|
|
|
|
File System Layout
|
|
------------------
|
|
|
|
The file system is mounted at:
|
|
|
|
/etc/pve
|
|
|
|
Files
|
|
~~~~~
|
|
|
|
[width="100%",cols="m,d"]
|
|
|=======
|
|
|`authkey.pub` | Public key used by the ticket system
|
|
|`ceph.conf` | Ceph configuration file (note: /etc/ceph/ceph.conf is a symbolic link to this)
|
|
|`corosync.conf` | Corosync cluster configuration file (prior to {pve} 4.x, this file was called cluster.conf)
|
|
|`datacenter.cfg` | {pve} datacenter-wide configuration (keyboard layout, proxy, ...)
|
|
|`domains.cfg` | {pve} authentication domains
|
|
|`firewall/cluster.fw` | Firewall configuration applied to all nodes
|
|
|`firewall/<NAME>.fw` | Firewall configuration for individual nodes
|
|
|`firewall/<VMID>.fw` | Firewall configuration for VMs and containers
|
|
|`ha/crm_commands` | Displays HA operations that are currently being carried out by the CRM
|
|
|`ha/manager_status` | JSON-formatted information regarding HA services on the cluster
|
|
|`ha/resources.cfg` | Resources managed by high availability, and their current state
|
|
|`nodes/<NAME>/config` | Node-specific configuration
|
|
|`nodes/<NAME>/lxc/<VMID>.conf` | VM configuration data for LXC containers
|
|
|`nodes/<NAME>/openvz/` | Prior to {pve} 4.0, used for container configuration data (deprecated, removed soon)
|
|
|`nodes/<NAME>/pve-ssl.key` | Private SSL key for `pve-ssl.pem`
|
|
|`nodes/<NAME>/pve-ssl.pem` | Public SSL certificate for web server (signed by cluster CA)
|
|
|`nodes/<NAME>/pveproxy-ssl.key` | Private SSL key for `pveproxy-ssl.pem` (optional)
|
|
|`nodes/<NAME>/pveproxy-ssl.pem` | Public SSL certificate (chain) for web server (optional override for `pve-ssl.pem`)
|
|
|`nodes/<NAME>/qemu-server/<VMID>.conf` | VM configuration data for KVM VMs
|
|
|`priv/authkey.key` | Private key used by ticket system
|
|
|`priv/authorized_keys` | SSH keys of cluster members for authentication
|
|
|`priv/ceph*` | Ceph authentication keys and associated capabilities
|
|
|`priv/known_hosts` | SSH keys of the cluster members for verification
|
|
|`priv/lock/*` | Lock files used by various services to ensure safe cluster-wide operations
|
|
|`priv/pve-root-ca.key` | Private key of cluster CA
|
|
|`priv/shadow.cfg` | Shadow password file for PVE Realm users
|
|
|`priv/storage/<STORAGE-ID>.pw` | Contains the password of a storage in plain text
|
|
|`priv/tfa.cfg` | Base64-encoded two-factor authentication configuration
|
|
|`priv/token.cfg` | API token secrets of all tokens
|
|
|`pve-root-ca.pem` | Public certificate of cluster CA
|
|
|`pve-www.key` | Private key used for generating CSRF tokens
|
|
|`sdn/*` | Shared configuration files for Software Defined Networking (SDN)
|
|
|`status.cfg` | {pve} external metrics server configuration
|
|
|`storage.cfg` | {pve} storage configuration
|
|
|`user.cfg` | {pve} access control configuration (users/groups/...)
|
|
|`virtual-guest/cpu-models.conf` | For storing custom CPU models
|
|
|`vzdump.cron` | Cluster-wide vzdump backup-job schedule
|
|
|=======
|
|
|
|
|
|
Symbolic links
|
|
~~~~~~~~~~~~~~
|
|
|
|
Certain directories within the cluster file system use symbolic links, in order
|
|
to point to a node's own configuration files. Thus, the files pointed to in the
|
|
table below refer to different files on each node of the cluster.
|
|
|
|
[width="100%",cols="m,m"]
|
|
|=======
|
|
|`local` | `nodes/<LOCAL_HOST_NAME>`
|
|
|`lxc` | `nodes/<LOCAL_HOST_NAME>/lxc/`
|
|
|`openvz` | `nodes/<LOCAL_HOST_NAME>/openvz/` (deprecated, removed soon)
|
|
|`qemu-server` | `nodes/<LOCAL_HOST_NAME>/qemu-server/`
|
|
|=======
|
|
|
|
|
|
Special status files for debugging (JSON)
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
[width="100%",cols="m,d"]
|
|
|=======
|
|
|`.version` |File versions (to detect file modifications)
|
|
|`.members` |Info about cluster members
|
|
|`.vmlist` |List of all VMs
|
|
|`.clusterlog` |Cluster log (last 50 entries)
|
|
|`.rrd` |RRD data (most recent entries)
|
|
|=======
|
|
|
|
|
|
Enable/Disable debugging
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
You can enable verbose syslog messages with:
|
|
|
|
echo "1" >/etc/pve/.debug
|
|
|
|
And disable verbose syslog messages with:
|
|
|
|
echo "0" >/etc/pve/.debug
|
|
|
|
|
|
Recovery
|
|
--------
|
|
|
|
If you have major problems with your {pve} host, for example hardware
|
|
issues, it could be helpful to copy the pmxcfs database file
|
|
`/var/lib/pve-cluster/config.db`, and move it to a new {pve}
|
|
host. On the new host (with nothing running), you need to stop the
|
|
`pve-cluster` service and replace the `config.db` file (required permissions
|
|
`0600`). Following this, adapt `/etc/hostname` and `/etc/hosts` according to the
|
|
lost {pve} host, then reboot and check (and don't forget your
|
|
VM/CT data).
|
|
|
|
|
|
Remove Cluster Configuration
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The recommended way is to reinstall the node after you remove it from
|
|
your cluster. This ensures that all secret cluster/ssh keys and any
|
|
shared configuration data is destroyed.
|
|
|
|
In some cases, you might prefer to put a node back to local mode without
|
|
reinstalling, which is described in
|
|
<<pvecm_separate_node_without_reinstall,Separate A Node Without Reinstalling>>
|
|
|
|
|
|
Recovering/Moving Guests from Failed Nodes
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
For the guest configuration files in `nodes/<NAME>/qemu-server/` (VMs) and
|
|
`nodes/<NAME>/lxc/` (containers), {pve} sees the containing node `<NAME>` as the
|
|
owner of the respective guest. This concept enables the usage of local locks
|
|
instead of expensive cluster-wide locks for preventing concurrent guest
|
|
configuration changes.
|
|
|
|
As a consequence, if the owning node of a guest fails (for example, due to a power
|
|
outage, fencing event, etc.), a regular migration is not possible (even if all
|
|
the disks are located on shared storage), because such a local lock on the
|
|
(offline) owning node is unobtainable. This is not a problem for HA-managed
|
|
guests, as {pve}'s High Availability stack includes the necessary
|
|
(cluster-wide) locking and watchdog functionality to ensure correct and
|
|
automatic recovery of guests from fenced nodes.
|
|
|
|
If a non-HA-managed guest has only shared disks (and no other local resources
|
|
which are only available on the failed node), a manual recovery
|
|
is possible by simply moving the guest configuration file from the failed
|
|
node's directory in `/etc/pve/` to an online node's directory (which changes the
|
|
logical owner or location of the guest).
|
|
|
|
For example, recovering the VM with ID `100` from an offline `node1` to another
|
|
node `node2` works by running the following command as root on any member node
|
|
of the cluster:
|
|
|
|
mv /etc/pve/nodes/node1/qemu-server/100.conf /etc/pve/nodes/node2/qemu-server/
|
|
|
|
WARNING: Before manually recovering a guest like this, make absolutely sure
|
|
that the failed source node is really powered off/fenced. Otherwise {pve}'s
|
|
locking principles are violated by the `mv` command, which can have unexpected
|
|
consequences.
|
|
|
|
WARNING: Guests with local disks (or other local resources which are only
|
|
available on the offline node) are not recoverable like this. Either wait for the
|
|
failed node to rejoin the cluster or restore such guests from backups.
|
|
|
|