[[storage_iscsidirect]]
User Mode iSCSI Backend
-----------------------
ifdef::wiki[]
:pve-toplevel:
:title: Storage: User Mode iSCSI
endif::wiki[]
Storage pool type: `iscsidirect`
This backend provides basically the same functionality as the Open-iSCSI backed,
but uses a user-level library to implement it. You need to install the
`libiscsi-bin` package in order to use this backend.
It should be noted that there are no kernel drivers involved, so this
can be viewed as performance optimization. But this comes with the
drawback that you cannot use LVM on top of such iSCSI LUN. So you need
to manage all space allocations at the storage server side.
Configuration
~~~~~~~~~~~~~
The user mode iSCSI backend uses the same configuration options as the
Open-iSCSI backed.
.Configuration Example (`/etc/pve/storage.cfg`)
----
iscsidirect: faststore
portal 10.10.10.1
target iqn.2006-01.openfiler.com:tsn.dcb5aaaddd
----
Storage Features
~~~~~~~~~~~~~~~~
NOTE: This backend works with VMs only. Containers cannot use this
driver.
.Storage features for backend `iscsidirect`
[width="100%",cols="m,m,3*d",options="header"]
|==============================================================================
|Content types |Image formats |Shared |Snapshots |Clones
|images |raw |yes |no |no
|==============================================================================
ifdef::wiki[]
See Also
~~~~~~~~
* link:/wiki/Storage[Storage]
endif::wiki[]