As otherwise we couple *all* Makefile targets to the dependencies of
the test script, even for a simple make call (e.g., done on building
the source), so use a much simpler heuristic that just depends on
perl, which is essential in Debian.
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
It's sufficient to depend on the version without the revision, because
4.1-1 is the first version of the package satisfying >= 4.1.
Signed-off-by: Fiona Ebner <f.ebner@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
which is the case for passed-through disks. The qemu_img_format()
function cannot correctly handle those, and it's not safe to assume
they are raw (it's most likely, but not guaranteed), so just use the
storage method for the format like it was done before commit
efa3aa24 ("avoid list context for volume_size_info calls"). This will
use 'qemu-img info' to get the actual format.
Reported in the community forum:
https://forum.proxmox.com/threads/124794/https://forum.proxmox.com/threads/124823/https://forum.proxmox.com/threads/124818/
Fixes: efa3aa24 ("avoid list context for volume_size_info calls")
Signed-off-by: Fiona Ebner <f.ebner@proxmox.com>
Tested-by: Friedrich Weber <f.weber@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
With the recent pve-storage commit d70d814 ("api: fix get content call response
type for RBD/ZFS/iSCSI volumes"), the volume_size_info call for RBD in
list context is much slower than before (from a quick test, about twice as long
without snapshots, even longer with snapshots and untested, but when using an
external cluster with image not having the fast-diff feature, it should be worse
still) and thus increases the likelihood to run into timeouts here.
None of the callers here actually need the more expensive call, so just
avoid calling in list context.
Signed-off-by: Fiona Ebner <f.ebner@proxmox.com>
While, usually, the slot should match the ID, it's not explicitly
guaranteed and relies on QEMU internals. Using the numerical ID is
more future-proof and more consistent with plugging, where no slot
information (except the maximum limit) is relied upon.
Signed-off-by: Fiona Ebner <f.ebner@proxmox.com>
current qemu_dimm_list can return any kind of memory devices.
make it more generic, with an optionnal type device
Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
in some nvidia grid drivers (e.g. 14.4 and 15.x), their kernel module
tries to clean up the mdev device when the vm is shutdown and if it
cannot do that (e.g. becaues we already cleaned it up), their removal
process cancels with an error such that the vgpu does still exist inside
their book-keeping, but can't be used/recreated/freed until a reboot.
since there seems no obvious way to detect if thats the case besides
either parsing dmesg (which is racy), or the nvidia kernel module
version(which i'd rather not do), we simply test the pci device vendor
for nvidia and add a 10s sleep. that should give the driver enough time
to clean up and we will not find the path anymore and skip the cleanup.
This way, it works with both the newer and older versions of the driver
(some of the older drivers are LTS releases, so they're still
supported).
Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
instead of using the mdev uuid. The nvidia driver does not actually care
that it's the same as the mdev, and in qemu the uuid parameter
overwrites the smbios1 uuid internally, so we should have been reusing
that in the first place.
Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
Respecting bandwidth limit for offline clone was implemented by commit
56d16f16 ("fix #4249: make image clone or conversion respect bandwidth
limit"). It's still not respected for EFI disks, but those are small,
so just ignore it.
Signed-off-by: Fiona Ebner <f.ebner@proxmox.com>
Previously, cloning a stopped VM didn't respect bwlimit. Passing the -r
(ratelimit) parameter to qemu-img convert fixes this issue.
Signed-off-by: Leo Nunner <l.nunner@proxmox.com>
[ T: reword subject line slightly ]
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
Avoid pretending that a MTU change on a existing network device gets
applied live to a running VM.
Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
[ T: reworded and expanded commit message slightly ]
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
Required because there's one single efi for ARM, and the 2m/4m
difference doesn't seem to apply.
Signed-off-by: Matthias Heiserer <m.heiserer@proxmox.com>
[ T: move description to format and reword subject ]
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
AFAICT, previously, errors from swtpm would not show up in any logs,
because they were just printed to the stderr of the daemonized
invocation here.
The 'truncate' option is not used, so that the log is not immediately
lost when a new instance is started. This increases the chance that
the relevant errors are still present when requesting the log from a
user.
Log level 1 contains the most relevant errors and seems to be quiet
for working-as-expected invocations. Log level 2 already includes
logging full TPM commands, some of which are 1024 bytes long. Thus,
log level 1 was chosen.
Signed-off-by: Fiona Ebner <f.ebner@proxmox.com>
The guest will be running, so it's misleading to fail the start task
here. Also ensures that we clean up the hibernation state upon resume
even if there is an error here, which did not happen previously[0].
[0]: https://forum.proxmox.com/threads/123159/
Signed-off-by: Fiona Ebner <f.ebner@proxmox.com>
The target of the drive-mirror operation is opened with (essentially)
the same flags as the source in QEMU, in particular whether io_uring
should be used is inherited.
But io_uring currently causes problems in combination with certain
storage types, sometimes even leading to crashes (LVM with Linux 6.1).
Just disallow live cloning of drives when the source uses io_uring and
the target storage is not ready for it. There is one exception, namely
when source and target storage are the same. In that case, just assume
it will keep working for the target.
Migration does not seem to be affected, because there, the target VM
opens the images with the checked aio setting and then NBD exports of
those are used as the targets for mirroring.
It can be that the default determined for the source is not what's
actually used, because after a drive-mirror to a storage with a
different default, it will still use the default from the old storage.
Unfortunately, aio doesn't seem to be part of the 'query-block' QMP
command's result, so just tolerate this edge case.
The check can be removed if either
1. drive-mirror learns to open the target with a different aio setting
or more ideally
2. there are no more bad storages for io_uring.
Signed-off-by: Fiona Ebner <f.ebner@proxmox.com>
Previously, changing aio would be applied to the configuration, but
the drive would still be using the old setting.
Signed-off-by: Fiona Ebner <f.ebner@proxmox.com>
Since commit 9b6efe43 ("migrate: add live-migration of replicated
disks") live-migration with replicated volumes is possible. When
handling the replication, it is checked that all local volumes
previously detected as replicatable are actually replicated. So the
check if migration with snapshots is possible can just allow volumes
that are detected as replicatable.
Note that VM state files are also replicated.
If there is an invalid configuration with a non-replicatable volume or
state file and replication is enabled, then replication will fail, and
thus migration will fail early.
Trying to live-migrate to a non-replication target (needs --force)
will still fail if there are snapshots, because they are (correctly)
detected as non-replicated.
Signed-off-by: Fiona Ebner <f.ebner@proxmox.com>
In the web UI, this was fixed years ago by pve-manager commit c11c4a40
("fix #1631: change units to binary prefix").
Quickly checked with the 'query-memory-size-summary' QMP command that
this is actually the case.
Signed-off-by: Fiona Ebner <f.ebner@proxmox.com>
The error messages for missing OVMF_CODE and OVMF_VARS files were
inconsistent as well as the error for the missing base var file not
telling you the expected path.
Signed-off-by: Noel Ullreich <n.ullreich@proxmox.com>