40a24f5ab9
Using *-dead_ip-1 resources to track on which nodes the ganesha.nfsd had died was found to be unreliable. Running `pcs status` in the ganesha_grace monitor action was seen to time out during failover; the HA devs opined that it was, generally, not a good idea to run `pcs status` in a monitor action in any event. They suggested using the notify feature, where the resources on all the nodes are notified when a clone resource agent dies. This change adds a notify action to the ganesha_grace RA. The ganesha_mon RA monitors its ganesha.nfsd daemon. While the daemon is running, it creates two attributes: ganesha-active and grace-active. When the daemon stops for any reason, the attributes are deleted. Deleting the ganesha-active attribute triggers the failover of the virtual IP (the IPaddr RA) to another node where ganesha.nfsd is still running. The ganesha_grace RA monitors the grace-active attribute. When the grace-active attibute is deleted, the ganesha_grace RA stops, and will not restart. This triggers pacemaker to trigger the notify action in the ganesha_grace RAs on the other nodes in the cluster; which send a DBUS message to their ganesha.nfsd. (N.B. grace-active is a bit of a misnomer. while the grace-active attribute exists, everything is normal and healthy. Deleting the attribute triggers putting the surviving ganesha.nfsds into GRACE.) To ensure that the remaining/surviving ganesha.nfsds are put into NFS-GRACE before the IPaddr (virtual IP) fails over there is a short delay (sleep) between deleting the grace-active attribute and the ganesha-active attribute. To summarize: 1. on node 2 ganesha_mon:monitor notices that ganesha.nfsd has died 2. on node 2 ganesha_mon:monitor deletes its grace-active attribute 3. on node 2 ganesha_grace:monitor notices that grace-active is gone and returns OCF_ERR_GENERIC, a.k.a. new error. When pacemaker tries to (re)start ganesha_grace, its start action will return OCF_NOT_RUNNING, a.k.a. known error, don't attempt further restarts. 4. on nodes 1, 3, etc., ganesha_grace:notify receives a post-stop notification indicating that node 2 is gone, and sends a DBUS message to its ganesha.nfsd putting it into NFS-GRACE. 5. on node 2 ganesha_mon:monitor waits a short period, then deletes its ganesha-active attribute. This triggers the IPaddr (virt IP) failover according to constraint location rules. ganesha_nfsd modified to run for the duration, start action is invoked to setup the /var/lib/nfs symlink, stop action is invoked to restore it. ganesha-ha.sh modified accordingly to create it as a clone resource. BUG: 1290865 Change-Id: I1ba24f38fa4338b3aeb17c65645e9f439387ff57 Signed-off-by: Kaleb S KEITHLEY <kkeithle@redhat.com> Reviewed-on: http://review.gluster.org/12964 Smoke: Gluster Build System <jenkins@build.gluster.com> NetBSD-regression: NetBSD Build System <jenkins@build.gluster.org> CentOS-regression: Gluster Build System <jenkins@build.gluster.com> Reviewed-on: http://review.gluster.org/13725
Admin Guide
The gluster administration guide is maintained at github. The browsable admin guide can be found here.
The doc patch has to be sent against the above mentioned repository.
Features/Spec
The Gluster features which are 'in progress' or implemented can be found at github.
Upgrade Guide
The gluster upgrade guide is maintained at github. The browsable upgrade guide can be found here
The doc patch has to be sent against the above mentioned repository.
For more details about the docuemntation workflow please refer this discussion