2019-05-27 09:55:01 +03:00
// SPDX-License-Identifier: GPL-2.0-or-later
2006-06-26 11:25:19 +04:00
/*
* Copyright ( C ) 2006 Jim Cromie
*
* This is a clocksource driver for the Geode SCx200 ' s 1 or 27 MHz
* high - resolution timer . The Geode SC - 1100 ( at least ) has a buggy
* time stamp counter ( TSC ) , which loses time unless ' idle = poll ' is
* given as a boot - arg . In its absence , the Generic Timekeeping code
* will detect and de - rate the bad TSC , allowing this timer to take
* over timekeeping duties .
*
* Based on work by John Stultz , and Ted Phelps ( in a 2.6 .12 - rc6 patch )
*/
# include <linux/clocksource.h>
# include <linux/init.h>
# include <linux/module.h>
# include <linux/ioport.h>
# include <linux/scx200.h>
# define NAME "scx200_hrt"
static int mhz27 ;
module_param ( mhz27 , int , 0 ) ; /* load time only */
MODULE_PARM_DESC ( mhz27 , " count at 27.0 MHz (default is 1.0 MHz) " ) ;
static int ppm ;
module_param ( ppm , int , 0 ) ; /* load time only */
MODULE_PARM_DESC ( ppm , " +-adjust to actual XO freq (ppm) " ) ;
/* HiRes Timer configuration register address */
# define SCx200_TMCNFG_OFFSET (SCx200_TIMER_OFFSET + 5)
/* and config settings */
# define HR_TMEN (1 << 0) /* timer interrupt enable */
# define HR_TMCLKSEL (1 << 1) /* 1|0 counts at 27|1 MHz */
# define HR_TM27MPD (1 << 2) /* 1 turns off input clock (power-down) */
/* The base timer frequency, * 27 if selected */
# define HRT_FREQ 1000000
2016-12-21 22:32:01 +03:00
static u64 read_hrt ( struct clocksource * cs )
2006-06-26 11:25:19 +04:00
{
/* Read the timer value */
2016-12-21 22:32:01 +03:00
return ( u64 ) inl ( scx200_cb_base + SCx200_TIMER_OFFSET ) ;
2006-06-26 11:25:19 +04:00
}
static struct clocksource cs_hrt = {
. name = " scx200_hrt " ,
. rating = 250 ,
. read = read_hrt ,
. mask = CLOCKSOURCE_MASK ( 32 ) ,
2007-02-16 12:27:36 +03:00
. flags = CLOCK_SOURCE_IS_CONTINUOUS ,
2006-06-26 11:25:19 +04:00
/* mult, shift are set based on mhz27 flag */
} ;
static int __init init_hrt_clocksource ( void )
{
2012-01-10 04:15:03 +04:00
u32 freq ;
2006-10-04 13:15:35 +04:00
/* Make sure scx200 has initialized the configuration block */
2006-06-26 11:25:19 +04:00
if ( ! scx200_cb_present ( ) )
return - ENODEV ;
/* Reserve the timer's ISA io-region for ourselves */
if ( ! request_region ( scx200_cb_base + SCx200_TIMER_OFFSET ,
SCx200_TIMER_SIZE ,
" NatSemi SCx200 High-Resolution Timer " ) ) {
2012-01-27 03:52:15 +04:00
pr_warn ( " unable to lock timer region \n " ) ;
2006-06-26 11:25:19 +04:00
return - ENODEV ;
}
/* write timer config */
2006-10-04 13:15:35 +04:00
outb ( HR_TMEN | ( mhz27 ? HR_TMCLKSEL : 0 ) ,
2006-06-26 11:25:19 +04:00
scx200_cb_base + SCx200_TMCNFG_OFFSET ) ;
2012-01-10 04:15:03 +04:00
freq = ( HRT_FREQ + ppm ) ;
if ( mhz27 )
freq * = 27 ;
2012-02-22 16:19:37 +04:00
pr_info ( " enabling scx200 high-res timer (%s MHz +%d ppm) \n " , mhz27 ? " 27 " : " 1 " , ppm ) ;
2006-06-26 11:25:19 +04:00
2012-01-10 04:15:03 +04:00
return clocksource_register_hz ( & cs_hrt , freq ) ;
2006-06-26 11:25:19 +04:00
}
module_init ( init_hrt_clocksource ) ;
MODULE_AUTHOR ( " Jim Cromie <jim.cromie@gmail.com> " ) ;
MODULE_DESCRIPTION ( " clocksource on SCx200 HiRes Timer " ) ;
MODULE_LICENSE ( " GPL " ) ;