2021-04-13 02:03:18 +03:00
# SPDX-License-Identifier: GPL-2.0
%YAML 1.2
---
$id : http://devicetree.org/schemas/power/supply/charger-manager.yaml#
$schema : http://devicetree.org/meta-schemas/core.yaml#
title : Charger Manager
maintainers :
- Sebastian Reichel <sre@kernel.org>
description : |
Binding for the legacy charger manager driver.
Please do not use for new products.
properties :
compatible :
const : charger-manager
cm-chargers :
description : name of chargers
$ref : /schemas/types.yaml#/definitions/string-array
cm-num-chargers :
$ref : /schemas/types.yaml#/definitions/uint32
deprecated : true
cm-fuel-gauge :
description : name of battery fuel gauge
$ref : /schemas/types.yaml#/definitions/string
cm-name :
description : name of the charger manager
default : battery
$ref : /schemas/types.yaml#/definitions/string
cm-poll-mode :
description : polling mode
2022-05-20 00:14:11 +03:00
$ref : /schemas/types.yaml#/definitions/uint32
2021-04-13 02:03:18 +03:00
default : 0
enum :
- 0 # disabled
- 1 # always
- 2 # when external power is connected
- 3 # when charging
cm-poll-interval :
description : polling interval (in ms)
$ref : /schemas/types.yaml#/definitions/uint32
cm-battery-stat :
description : battery status
2022-07-20 00:50:16 +03:00
$ref : /schemas/types.yaml#/definitions/uint32
2021-04-13 02:03:18 +03:00
enum :
- 0 # battery always present
- 1 # no battery
- 2 # check presence via fuel gauge
- 3 # check presence via charger
cm-fullbatt-vchkdrop-volt :
description : voltage drop before restarting charging in uV
$ref : /schemas/types.yaml#/definitions/uint32
cm-fullbatt-vchkdrop-ms :
deprecated : true
cm-fullbatt-voltage :
description : voltage of full battery in uV
$ref : /schemas/types.yaml#/definitions/uint32
cm-fullbatt-soc :
description : state of charge to consider as full battery in %
$ref : /schemas/types.yaml#/definitions/uint32
cm-fullbatt-capacity :
description : capcity to consider as full battery in uAh
$ref : /schemas/types.yaml#/definitions/uint32
cm-thermal-zone :
description : name of external thermometer's thermal zone
$ref : /schemas/types.yaml#/definitions/string
cm-discharging-max :
description : limits of discharging duration in ms
$ref : /schemas/types.yaml#/definitions/uint32
cm-charging-max :
description : limits of charging duration in ms
$ref : /schemas/types.yaml#/definitions/uint32
cm-battery-cold :
description : critical cold temperature of battery for charging in deci-degree celsius
$ref : /schemas/types.yaml#/definitions/uint32
cm-battery-cold-in-minus :
description : if set cm-battery-cold temperature is in minus degrees
type : boolean
cm-battery-hot :
description : critical hot temperature of battery for charging in deci-degree celsius
$ref : /schemas/types.yaml#/definitions/uint32
cm-battery-temp-diff :
description : temperature difference to allow recharging in deci-degree celsius
$ref : /schemas/types.yaml#/definitions/uint32
patternProperties :
"-supply$" :
description : regulator consumer, named according to cm-regulator-name
$ref : /schemas/types.yaml#/definitions/phandle
"^regulator[@-][0-9]$" :
type : object
properties :
cm-regulator-name :
description : name of charger regulator
$ref : /schemas/types.yaml#/definitions/string
required :
- cm-regulator-name
additionalProperties : false
patternProperties :
"^cable[@-][0-9]$" :
type : object
properties :
cm-cable-name :
description : name of charger cable
enum :
- USB
- USB-HOST
- SDP
- DCP
- CDP
- ACA
- FAST-CHARGER
- SLOW-CHARGER
- WPT
- PD
- DOCK
- JIG
- MECHANICAL
cm-cable-extcon :
description : name of extcon dev
$ref : /schemas/types.yaml#/definitions/string
cm-cable-min :
description : minimum current of cable in uA
$ref : /schemas/types.yaml#/definitions/uint32
cm-cable-max :
description : maximum current of cable in uA
$ref : /schemas/types.yaml#/definitions/uint32
required :
- cm-cable-name
- cm-cable-extcon
additionalProperties : false
required :
- compatible
- cm-chargers
- cm-fuel-gauge
additionalProperties : false
examples :
- |
charger-manager {
compatible = "charger-manager";
chg-reg-supply = <&charger_regulator>;
cm-name = "battery";
/* Always polling ON : 30s */
cm-poll-mode = <1>;
cm-poll-interval = <30000>;
cm-fullbatt-vchkdrop-volt = <150000>;
cm-fullbatt-soc = <100>;
cm-battery-stat = <3>;
cm-chargers = "charger0", "charger1", "charger2";
cm-fuel-gauge = "fuelgauge0";
cm-thermal-zone = "thermal_zone.1";
/* in deci centigrade */
cm-battery-cold = <50>;
cm-battery-cold-in-minus;
cm-battery-hot = <800>;
cm-battery-temp-diff = <100>;
/* Allow charging for 5hr */
cm-charging-max = <18000000>;
/* Allow discharging for 2hr */
cm-discharging-max = <7200000>;
regulator-0 {
cm-regulator-name = "chg-reg";
cable-0 {
cm-cable-name = "USB";
cm-cable-extcon = "extcon-dev.0";
cm-cable-min = <475000>;
cm-cable-max = <500000>;
};
cable-1 {
cm-cable-name = "SDP";
cm-cable-extcon = "extcon-dev.0";
cm-cable-min = <650000>;