net: axienet: reset core on initialization prior to MDIO access
In some cases where the Xilinx Ethernet core was used in 1000Base-X or SGMII modes, which use the internal PCS/PMA PHY, and the MGT transceiver clock source for the PCS was not running at the time the FPGA logic was loaded, the core would come up in a state where the PCS could not be found on the MDIO bus. To fix this, the Ethernet core (including the PCS) should be reset after enabling the clocks, prior to attempting to access the PCS using of_mdio_find_device. Fixes: 1a02556086fc (net: axienet: Properly handle PCS/PMA PHY for 1000BaseX mode) Signed-off-by: Robert Hancock <robert.hancock@calian.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
b400c2f4f4
commit
04cc2da396
@ -2036,6 +2036,11 @@ static int axienet_probe(struct platform_device *pdev)
|
||||
lp->coalesce_count_rx = XAXIDMA_DFT_RX_THRESHOLD;
|
||||
lp->coalesce_count_tx = XAXIDMA_DFT_TX_THRESHOLD;
|
||||
|
||||
/* Reset core now that clocks are enabled, prior to accessing MDIO */
|
||||
ret = __axienet_device_reset(lp);
|
||||
if (ret)
|
||||
goto cleanup_clk;
|
||||
|
||||
lp->phy_node = of_parse_phandle(pdev->dev.of_node, "phy-handle", 0);
|
||||
if (lp->phy_node) {
|
||||
ret = axienet_mdio_setup(lp);
|
||||
|