serial: max310x: Fix tx_empty() callback

[ Upstream commit a8da3c7873ea57acb8f9cea58c0af477522965aa ]

Function max310x_tx_empty() accesses the IRQSTS register, which is
cleared by IC when reading, so if there is an interrupt status, we
will lose it. This patch implement the transmitter check only by
the current FIFO level.

Signed-off-by: Alexander Shiyan <shc_work@mail.ru>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
Alexander Shiyan 2018-12-19 14:19:20 +03:00 committed by Greg Kroah-Hartman
parent c6418ce8b8
commit 077d879930

View File

@ -769,12 +769,9 @@ static void max310x_start_tx(struct uart_port *port)
static unsigned int max310x_tx_empty(struct uart_port *port)
{
unsigned int lvl, sts;
u8 lvl = max310x_port_read(port, MAX310X_TXFIFOLVL_REG);
lvl = max310x_port_read(port, MAX310X_TXFIFOLVL_REG);
sts = max310x_port_read(port, MAX310X_IRQSTS_REG);
return ((sts & MAX310X_IRQ_TXEMPTY_BIT) && !lvl) ? TIOCSER_TEMT : 0;
return lvl ? 0 : TIOCSER_TEMT;
}
static unsigned int max310x_get_mctrl(struct uart_port *port)