thermal: exynos: Propagate error value from tmu_read()
tmu_read() in case of Exynos4210 might return error for out of bound values. Current code ignores such value, what leads to reporting critical temperature value. Add proper error code propagation to exynos_get_temp() function. Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com> CC: stable@vger.kernel.org # v4.6+ Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
0eb875d88a
commit
08d725cd93
@ -892,6 +892,7 @@ static void exynos7_tmu_control(struct platform_device *pdev, bool on)
|
|||||||
static int exynos_get_temp(void *p, int *temp)
|
static int exynos_get_temp(void *p, int *temp)
|
||||||
{
|
{
|
||||||
struct exynos_tmu_data *data = p;
|
struct exynos_tmu_data *data = p;
|
||||||
|
int value, ret = 0;
|
||||||
|
|
||||||
if (!data || !data->tmu_read || !data->enabled)
|
if (!data || !data->tmu_read || !data->enabled)
|
||||||
return -EINVAL;
|
return -EINVAL;
|
||||||
@ -899,12 +900,16 @@ static int exynos_get_temp(void *p, int *temp)
|
|||||||
mutex_lock(&data->lock);
|
mutex_lock(&data->lock);
|
||||||
clk_enable(data->clk);
|
clk_enable(data->clk);
|
||||||
|
|
||||||
*temp = code_to_temp(data, data->tmu_read(data)) * MCELSIUS;
|
value = data->tmu_read(data);
|
||||||
|
if (value < 0)
|
||||||
|
ret = value;
|
||||||
|
else
|
||||||
|
*temp = code_to_temp(data, value) * MCELSIUS;
|
||||||
|
|
||||||
clk_disable(data->clk);
|
clk_disable(data->clk);
|
||||||
mutex_unlock(&data->lock);
|
mutex_unlock(&data->lock);
|
||||||
|
|
||||||
return 0;
|
return ret;
|
||||||
}
|
}
|
||||||
|
|
||||||
#ifdef CONFIG_THERMAL_EMULATION
|
#ifdef CONFIG_THERMAL_EMULATION
|
||||||
|
Loading…
x
Reference in New Issue
Block a user