net: phy: sfp: hwmon: Fix scaling of RX power
The RX power read from the SFP uses units of 0.1uW. This must be scaled to units of uW for HWMON. This requires a divide by 10, not the current 100. With this change in place, sensors(1) and ethtool -m agree: sff2-isa-0000 Adapter: ISA adapter in0: +3.23 V temp1: +33.1 C power1: 270.00 uW power2: 200.00 uW curr1: +0.01 A Laser output power : 0.2743 mW / -5.62 dBm Receiver signal average optical power : 0.2014 mW / -6.96 dBm Reported-by: chris.healy@zii.aero Signed-off-by: Andrew Lunn <andrew@lunn.ch> Fixes: 1323061a018a ("net: phy: sfp: Add HWMON support for module sensors") Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
503d81d428
commit
0cea0e1148
@ -517,7 +517,7 @@ static int sfp_hwmon_read_sensor(struct sfp *sfp, int reg, long *value)
|
||||
|
||||
static void sfp_hwmon_to_rx_power(long *value)
|
||||
{
|
||||
*value = DIV_ROUND_CLOSEST(*value, 100);
|
||||
*value = DIV_ROUND_CLOSEST(*value, 10);
|
||||
}
|
||||
|
||||