regulator: core: Add error flags to sysfs attributes
If a regulator provides a get_error_flags() operation, its sysfs attributes will now include an entry for each defined REGULATOR_ERROR_* flag. Signed-off-by: Zev Weiss <zev@bewilderbeest.net> Link: https://lore.kernel.org/r/20220504065252.6955-3-zev@bewilderbeest.net Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
parent
20078e3bbe
commit
0f2d636e7d
@ -370,3 +370,84 @@ Description:
|
|||||||
|
|
||||||
'unknown' means software cannot determine the state, or
|
'unknown' means software cannot determine the state, or
|
||||||
the reported state is invalid.
|
the reported state is invalid.
|
||||||
|
|
||||||
|
What: /sys/class/regulator/.../under_voltage
|
||||||
|
Date: April 2022
|
||||||
|
KernelVersion: 5.18
|
||||||
|
Contact: Zev Weiss <zev@bewilderbeest.net>
|
||||||
|
Description:
|
||||||
|
Some regulator directories will contain a field called
|
||||||
|
under_voltage. This indicates if the device reports an
|
||||||
|
under-voltage fault (1) or not (0).
|
||||||
|
|
||||||
|
What: /sys/class/regulator/.../over_current
|
||||||
|
Date: April 2022
|
||||||
|
KernelVersion: 5.18
|
||||||
|
Contact: Zev Weiss <zev@bewilderbeest.net>
|
||||||
|
Description:
|
||||||
|
Some regulator directories will contain a field called
|
||||||
|
over_current. This indicates if the device reports an
|
||||||
|
over-current fault (1) or not (0).
|
||||||
|
|
||||||
|
What: /sys/class/regulator/.../regulation_out
|
||||||
|
Date: April 2022
|
||||||
|
KernelVersion: 5.18
|
||||||
|
Contact: Zev Weiss <zev@bewilderbeest.net>
|
||||||
|
Description:
|
||||||
|
Some regulator directories will contain a field called
|
||||||
|
regulation_out. This indicates if the device reports an
|
||||||
|
out-of-regulation fault (1) or not (0).
|
||||||
|
|
||||||
|
What: /sys/class/regulator/.../fail
|
||||||
|
Date: April 2022
|
||||||
|
KernelVersion: 5.18
|
||||||
|
Contact: Zev Weiss <zev@bewilderbeest.net>
|
||||||
|
Description:
|
||||||
|
Some regulator directories will contain a field called
|
||||||
|
fail. This indicates if the device reports an output failure
|
||||||
|
(1) or not (0).
|
||||||
|
|
||||||
|
What: /sys/class/regulator/.../over_temp
|
||||||
|
Date: April 2022
|
||||||
|
KernelVersion: 5.18
|
||||||
|
Contact: Zev Weiss <zev@bewilderbeest.net>
|
||||||
|
Description:
|
||||||
|
Some regulator directories will contain a field called
|
||||||
|
over_temp. This indicates if the device reports an
|
||||||
|
over-temperature fault (1) or not (0).
|
||||||
|
|
||||||
|
What: /sys/class/regulator/.../under_voltage_warn
|
||||||
|
Date: April 2022
|
||||||
|
KernelVersion: 5.18
|
||||||
|
Contact: Zev Weiss <zev@bewilderbeest.net>
|
||||||
|
Description:
|
||||||
|
Some regulator directories will contain a field called
|
||||||
|
under_voltage_warn. This indicates if the device reports an
|
||||||
|
under-voltage warning (1) or not (0).
|
||||||
|
|
||||||
|
What: /sys/class/regulator/.../over_current_warn
|
||||||
|
Date: April 2022
|
||||||
|
KernelVersion: 5.18
|
||||||
|
Contact: Zev Weiss <zev@bewilderbeest.net>
|
||||||
|
Description:
|
||||||
|
Some regulator directories will contain a field called
|
||||||
|
over_current_warn. This indicates if the device reports an
|
||||||
|
over-current warning (1) or not (0).
|
||||||
|
|
||||||
|
What: /sys/class/regulator/.../over_voltage_warn
|
||||||
|
Date: April 2022
|
||||||
|
KernelVersion: 5.18
|
||||||
|
Contact: Zev Weiss <zev@bewilderbeest.net>
|
||||||
|
Description:
|
||||||
|
Some regulator directories will contain a field called
|
||||||
|
over_voltage_warn. This indicates if the device reports an
|
||||||
|
over-voltage warning (1) or not (0).
|
||||||
|
|
||||||
|
What: /sys/class/regulator/.../over_temp_warn
|
||||||
|
Date: April 2022
|
||||||
|
KernelVersion: 5.18
|
||||||
|
Contact: Zev Weiss <zev@bewilderbeest.net>
|
||||||
|
Description:
|
||||||
|
Some regulator directories will contain a field called
|
||||||
|
over_temp_warn. This indicates if the device reports an
|
||||||
|
over-temperature warning (1) or not (0).
|
||||||
|
@ -83,6 +83,7 @@ struct regulator_supply_alias {
|
|||||||
|
|
||||||
static int _regulator_is_enabled(struct regulator_dev *rdev);
|
static int _regulator_is_enabled(struct regulator_dev *rdev);
|
||||||
static int _regulator_disable(struct regulator *regulator);
|
static int _regulator_disable(struct regulator *regulator);
|
||||||
|
static int _regulator_get_error_flags(struct regulator_dev *rdev, unsigned int *flags);
|
||||||
static int _regulator_get_current_limit(struct regulator_dev *rdev);
|
static int _regulator_get_current_limit(struct regulator_dev *rdev);
|
||||||
static unsigned int _regulator_get_mode(struct regulator_dev *rdev);
|
static unsigned int _regulator_get_mode(struct regulator_dev *rdev);
|
||||||
static int _notifier_call_chain(struct regulator_dev *rdev,
|
static int _notifier_call_chain(struct regulator_dev *rdev,
|
||||||
@ -911,6 +912,30 @@ static ssize_t bypass_show(struct device *dev,
|
|||||||
}
|
}
|
||||||
static DEVICE_ATTR_RO(bypass);
|
static DEVICE_ATTR_RO(bypass);
|
||||||
|
|
||||||
|
#define REGULATOR_ERROR_ATTR(name, bit) \
|
||||||
|
static ssize_t name##_show(struct device *dev, struct device_attribute *attr, \
|
||||||
|
char *buf) \
|
||||||
|
{ \
|
||||||
|
int ret; \
|
||||||
|
unsigned int flags; \
|
||||||
|
struct regulator_dev *rdev = dev_get_drvdata(dev); \
|
||||||
|
ret = _regulator_get_error_flags(rdev, &flags); \
|
||||||
|
if (ret) \
|
||||||
|
return ret; \
|
||||||
|
return sysfs_emit(buf, "%d\n", !!(flags & (bit))); \
|
||||||
|
} \
|
||||||
|
static DEVICE_ATTR_RO(name)
|
||||||
|
|
||||||
|
REGULATOR_ERROR_ATTR(under_voltage, REGULATOR_ERROR_UNDER_VOLTAGE);
|
||||||
|
REGULATOR_ERROR_ATTR(over_current, REGULATOR_ERROR_OVER_CURRENT);
|
||||||
|
REGULATOR_ERROR_ATTR(regulation_out, REGULATOR_ERROR_REGULATION_OUT);
|
||||||
|
REGULATOR_ERROR_ATTR(fail, REGULATOR_ERROR_FAIL);
|
||||||
|
REGULATOR_ERROR_ATTR(over_temp, REGULATOR_ERROR_OVER_TEMP);
|
||||||
|
REGULATOR_ERROR_ATTR(under_voltage_warn, REGULATOR_ERROR_UNDER_VOLTAGE_WARN);
|
||||||
|
REGULATOR_ERROR_ATTR(over_current_warn, REGULATOR_ERROR_OVER_CURRENT_WARN);
|
||||||
|
REGULATOR_ERROR_ATTR(over_voltage_warn, REGULATOR_ERROR_OVER_VOLTAGE_WARN);
|
||||||
|
REGULATOR_ERROR_ATTR(over_temp_warn, REGULATOR_ERROR_OVER_TEMP_WARN);
|
||||||
|
|
||||||
/* Calculate the new optimum regulator operating mode based on the new total
|
/* Calculate the new optimum regulator operating mode based on the new total
|
||||||
* consumer load. All locks held by caller
|
* consumer load. All locks held by caller
|
||||||
*/
|
*/
|
||||||
@ -4984,6 +5009,15 @@ static struct attribute *regulator_dev_attrs[] = {
|
|||||||
&dev_attr_max_microvolts.attr,
|
&dev_attr_max_microvolts.attr,
|
||||||
&dev_attr_min_microamps.attr,
|
&dev_attr_min_microamps.attr,
|
||||||
&dev_attr_max_microamps.attr,
|
&dev_attr_max_microamps.attr,
|
||||||
|
&dev_attr_under_voltage.attr,
|
||||||
|
&dev_attr_over_current.attr,
|
||||||
|
&dev_attr_regulation_out.attr,
|
||||||
|
&dev_attr_fail.attr,
|
||||||
|
&dev_attr_over_temp.attr,
|
||||||
|
&dev_attr_under_voltage_warn.attr,
|
||||||
|
&dev_attr_over_current_warn.attr,
|
||||||
|
&dev_attr_over_voltage_warn.attr,
|
||||||
|
&dev_attr_over_temp_warn.attr,
|
||||||
&dev_attr_suspend_standby_state.attr,
|
&dev_attr_suspend_standby_state.attr,
|
||||||
&dev_attr_suspend_mem_state.attr,
|
&dev_attr_suspend_mem_state.attr,
|
||||||
&dev_attr_suspend_disk_state.attr,
|
&dev_attr_suspend_disk_state.attr,
|
||||||
@ -5039,6 +5073,17 @@ static umode_t regulator_attr_is_visible(struct kobject *kobj,
|
|||||||
if (attr == &dev_attr_bypass.attr)
|
if (attr == &dev_attr_bypass.attr)
|
||||||
return ops->get_bypass ? mode : 0;
|
return ops->get_bypass ? mode : 0;
|
||||||
|
|
||||||
|
if (attr == &dev_attr_under_voltage.attr ||
|
||||||
|
attr == &dev_attr_over_current.attr ||
|
||||||
|
attr == &dev_attr_regulation_out.attr ||
|
||||||
|
attr == &dev_attr_fail.attr ||
|
||||||
|
attr == &dev_attr_over_temp.attr ||
|
||||||
|
attr == &dev_attr_under_voltage_warn.attr ||
|
||||||
|
attr == &dev_attr_over_current_warn.attr ||
|
||||||
|
attr == &dev_attr_over_voltage_warn.attr ||
|
||||||
|
attr == &dev_attr_over_temp_warn.attr)
|
||||||
|
return ops->get_error_flags ? mode : 0;
|
||||||
|
|
||||||
/* constraints need specific supporting methods */
|
/* constraints need specific supporting methods */
|
||||||
if (attr == &dev_attr_min_microvolts.attr ||
|
if (attr == &dev_attr_min_microvolts.attr ||
|
||||||
attr == &dev_attr_max_microvolts.attr)
|
attr == &dev_attr_max_microvolts.attr)
|
||||||
|