scsi: smartpqi_init: fix boolean expression in pqi_device_remove_start
Fix boolean expression by using logical AND operator '&&' instead of
bitwise operator '&'.
This issue was detected with the help of Coccinelle.
Fixes: 1e46731efd
("scsi: smartpqi: check for null device pointers")
Signed-off-by: Gustavo A. R. Silva <gustavo@embeddedor.com>
Signed-off-by: Gustavo A. R. Silva <gustavo@embeddedor.com>
Acked-by: Don Brace <don.brace@microsemi.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
parent
3f7e62bba0
commit
12de280b36
@ -323,7 +323,7 @@ static inline void pqi_device_remove_start(struct pqi_scsi_dev *device)
|
||||
static inline bool pqi_device_in_remove(struct pqi_ctrl_info *ctrl_info,
|
||||
struct pqi_scsi_dev *device)
|
||||
{
|
||||
return device->in_remove & !ctrl_info->in_shutdown;
|
||||
return device->in_remove && !ctrl_info->in_shutdown;
|
||||
}
|
||||
|
||||