ath10k: remove send completion validation in diag read/write

CE diag window access is serialized (it has to be by design) so
there's no way to get a different send completion. so there's no
need for post completion validation.

Signed-off-by: Rajkumar Manoharan <rmanohar@qti.qualcomm.com>
Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>
This commit is contained in:
Rajkumar Manoharan 2015-10-23 18:01:04 +05:30 committed by Kalle Valo
parent b4e84c5606
commit 1e8f86d9cb

View File

@ -920,16 +920,6 @@ static int ath10k_pci_diag_read_mem(struct ath10k *ar, u32 address, void *data,
}
}
if (nbytes != completed_nbytes) {
ret = -EIO;
goto done;
}
if (buf != (u32)address) {
ret = -EIO;
goto done;
}
i = 0;
while (ath10k_ce_completed_recv_next_nolock(ce_diag, NULL, &buf,
&completed_nbytes,
@ -1094,16 +1084,6 @@ static int ath10k_pci_diag_write_mem(struct ath10k *ar, u32 address,
}
}
if (nbytes != completed_nbytes) {
ret = -EIO;
goto done;
}
if (buf != ce_data) {
ret = -EIO;
goto done;
}
i = 0;
while (ath10k_ce_completed_recv_next_nolock(ce_diag, NULL, &buf,
&completed_nbytes,