ARM: dts: imx7d: Add missing cooling device properties for CPUs
The cooling device properties "#cooling-cells" should either be present for all the CPUs of a cluster or none. If these are present only for a subset of CPUs of a cluster then things will start falling apart as soon as the CPUs are brought online in a different order. For example, this will happen because the operating system looks for such properties in the CPU node it is trying to bring up, so that it can register a cooling device. Add such missing properties. Signed-off-by: Anson Huang <Anson.Huang@nxp.com> Signed-off-by: Shawn Guo <shawnguo@kernel.org>
This commit is contained in:
parent
def76ebc7c
commit
28e95b7dcc
@ -22,6 +22,7 @@
|
||||
reg = <1>;
|
||||
clock-frequency = <996000000>;
|
||||
operating-points-v2 = <&cpu0_opp_table>;
|
||||
#cooling-cells = <2>;
|
||||
cpu-idle-states = <&cpu_sleep_wait>;
|
||||
};
|
||||
};
|
||||
|
Loading…