ARM: tegra: paz00: Add CPU thermal zone
Add thermal zone with a passive cooling trip for CPU. Attach it to the LM90 sensor which monitors CPU temperature. Now CPU frequencies will be throttled once trip point is reached, preventing critical overheat. Tested-by: Agneli <poczt@protonmail.ch> Tested-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Dmitry Osipenko <digetx@gmail.com> Signed-off-by: Thierry Reding <treding@nvidia.com>
This commit is contained in:
parent
5f45da704d
commit
2e09908f37
@ -2,6 +2,8 @@
|
||||
/dts-v1/;
|
||||
|
||||
#include <dt-bindings/input/input.h>
|
||||
#include <dt-bindings/thermal/thermal.h>
|
||||
|
||||
#include "tegra20.dtsi"
|
||||
#include "tegra20-cpu-opp.dtsi"
|
||||
#include "tegra20-cpu-opp-microvolt.dtsi"
|
||||
@ -498,9 +500,10 @@
|
||||
};
|
||||
};
|
||||
|
||||
adt7461@4c {
|
||||
adt7461: temperature-sensor@4c {
|
||||
compatible = "adi,adt7461";
|
||||
reg = <0x4c>;
|
||||
#thermal-sensor-cells = <1>;
|
||||
};
|
||||
};
|
||||
|
||||
@ -655,11 +658,46 @@
|
||||
cpu0: cpu@0 {
|
||||
cpu-supply = <&cpu_vdd_reg>;
|
||||
operating-points-v2 = <&cpu0_opp_table>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu@1 {
|
||||
cpu1: cpu@1 {
|
||||
cpu-supply = <&cpu_vdd_reg>;
|
||||
operating-points-v2 = <&cpu0_opp_table>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zones {
|
||||
cpu-thermal {
|
||||
polling-delay-passive = <500>; /* milliseconds */
|
||||
polling-delay = <1500>; /* milliseconds */
|
||||
|
||||
thermal-sensors = <&adt7461 1>;
|
||||
|
||||
trips {
|
||||
trip0: cpu-alert0 {
|
||||
/* start throttling at 80C */
|
||||
temperature = <80000>;
|
||||
hysteresis = <200>;
|
||||
type = "passive";
|
||||
};
|
||||
|
||||
trip1: cpu-crit {
|
||||
/* shut down at 85C */
|
||||
temperature = <85000>;
|
||||
hysteresis = <2000>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&trip0>;
|
||||
cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
|