i40e: reinit buffer size each time
When cleaning the ARQ, we must reinitialize the buffer size each time we go through the loop, because i40e_clean_arq_element returns the message length in the same field. Without this change, subsequent messages can be truncated to the length of the previous message. Change-Id: Ic9c32ff843faf0fc3196d21351a1c3a60c6158eb Signed-off-by: Mitch Williams <mitch.a.williams@intel.com> Signed-off-by: Jesse Brandeburg <jesse.brandeburg@intel.com> Tested-by: Kavindya Deegala <kavindya.s.deegala@intel.com> Tested-by: Sibai Li <sibai.li@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
This commit is contained in:
parent
2ef28cfb09
commit
2f0191238d
@ -4493,12 +4493,12 @@ static void i40e_clean_adminq_subtask(struct i40e_pf *pf)
|
||||
if (!test_bit(__I40E_ADMINQ_EVENT_PENDING, &pf->state))
|
||||
return;
|
||||
|
||||
event.msg_size = I40E_MAX_AQ_BUF_SIZE;
|
||||
event.msg_buf = kzalloc(event.msg_size, GFP_KERNEL);
|
||||
if (!event.msg_buf)
|
||||
return;
|
||||
|
||||
do {
|
||||
event.msg_size = I40E_MAX_AQ_BUF_SIZE; /* reinit each time */
|
||||
ret = i40e_clean_arq_element(hw, &event, &pending);
|
||||
if (ret == I40E_ERR_ADMIN_QUEUE_NO_WORK) {
|
||||
dev_info(&pf->pdev->dev, "No ARQ event found\n");
|
||||
|