thermal: stm32: Fix low threshold interrupt flood
With the STM32 thermal peripheral, it is not possible to dump the temperature that has caused the interrupt. When the temperature reaches the low threshold, we generally read a temperature that is a little bit higher than the low threshold. This maybe due to sampling precision, and also because the CPU becomes hotter when it quits WFI mode. In that case, the framework does not change the trip points. This leads to a lot of low threshold interrupts. The fix is to set the low threshold value 0.5 degrees Celsius below the actual request. The problem is not so frequent with the high threshold and it would no be a good idea to set the threshold value higher than the request. Signed-off-by: Pascal Paillet <p.paillet@st.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/20200110101605.24984-7-p.paillet@st.com
This commit is contained in:
parent
9d8593f22e
commit
2f23e319b1
@ -321,7 +321,8 @@ static int stm_thermal_set_trips(void *data, int low, int high)
|
||||
|
||||
if (low > -INT_MAX) {
|
||||
sensor->low_temp_enabled = 1;
|
||||
ret = stm_thermal_calculate_threshold(sensor, low, &th);
|
||||
/* add 0.5 of hysteresis due to measurement error */
|
||||
ret = stm_thermal_calculate_threshold(sensor, low - 500, &th);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
|
Loading…