hwmon: (nct7802) Fix voltage limits to wrong registers

commit 7713e62c8623c54dac88d1fa724aa487a38c3efb upstream.

in0 thresholds are written to the in2 thresholds registers
in2 thresholds to in3 thresholds
in3 thresholds to in4 thresholds
in4 thresholds to in0 thresholds

Signed-off-by: Gilles Buloz <gilles.buloz@kontron.com>
Link: https://lore.kernel.org/r/5de0f509.rc0oEvPOMjbfPW1w%gilles.buloz@kontron.com
Fixes: 3434f3783580 ("hwmon: Driver for Nuvoton NCT7802Y")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Gilles Buloz 2019-11-27 18:09:34 +01:00 committed by Greg Kroah-Hartman
parent 71befe0afd
commit 31710ab4b2

View File

@ -32,8 +32,8 @@
static const u8 REG_VOLTAGE[5] = { 0x09, 0x0a, 0x0c, 0x0d, 0x0e };
static const u8 REG_VOLTAGE_LIMIT_LSB[2][5] = {
{ 0x40, 0x00, 0x42, 0x44, 0x46 },
{ 0x3f, 0x00, 0x41, 0x43, 0x45 },
{ 0x46, 0x00, 0x40, 0x42, 0x44 },
{ 0x45, 0x00, 0x3f, 0x41, 0x43 },
};
static const u8 REG_VOLTAGE_LIMIT_MSB[5] = { 0x48, 0x00, 0x47, 0x47, 0x48 };