iio: adc: ad7606: fix reading unnecessary data from device
When a conversion result is being read from ADC, the driver reads the
number of channels + 1 because it thinks that IIO_CHAN_SOFT_TIMESTAMP
is also a physical channel. This patch fixes this issue.
Fixes: 2985a5d884
("staging: iio: adc: ad7606: Move out of staging")
Reported-by: Robert Wörle <rwoerle@mibtec.de>
Signed-off-by: Beniamin Bia <beniamin.bia@analog.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
committed by
Jonathan Cameron
parent
2611045e35
commit
341826a065
@ -85,7 +85,7 @@ err_unlock:
|
|||||||
|
|
||||||
static int ad7606_read_samples(struct ad7606_state *st)
|
static int ad7606_read_samples(struct ad7606_state *st)
|
||||||
{
|
{
|
||||||
unsigned int num = st->chip_info->num_channels;
|
unsigned int num = st->chip_info->num_channels - 1;
|
||||||
u16 *data = st->data;
|
u16 *data = st->data;
|
||||||
int ret;
|
int ret;
|
||||||
|
|
||||||
|
Reference in New Issue