staging: comedi: cb_pcidas: fix the ao cmd->start_arg use for TRIG_INT
This driver only supports a cmd->start_src of TRIG_INT for ai commands. The cmd->start_arg is trivially validated to be 0. For TRIG_INT source, the cmd->start_arg is actually the valid trig_num that is passed to the async (*inttrig) callback. Refactor the (*inttrig) function so that the cmd->start_arg is used to check the trig_num instead of the open coded value. Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com> Reviewed-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
96997b0efa
commit
384e483fb9
@ -1169,7 +1169,7 @@ static int cb_pcidas_ao_inttrig(struct comedi_device *dev,
|
||||
struct comedi_cmd *cmd = &s->async->cmd;
|
||||
unsigned long flags;
|
||||
|
||||
if (trig_num != 0)
|
||||
if (trig_num != cmd->start_arg)
|
||||
return -EINVAL;
|
||||
|
||||
/* load up fifo */
|
||||
|