drm/panel: simple: Fix Innolux G101ICE-L01 timings
The Innolux G101ICE-L01 datasheet [1] page 17 table 6.1 INPUT SIGNAL TIMING SPECIFICATIONS indicates that maximum vertical blanking time is 40 lines. Currently the driver uses 29 lines. Fix it, and since this panel is a DE panel, adjust the timings to make them less hostile to controllers which cannot do 1 px HSA/VSA, distribute the delays evenly between all three parts. [1] https://www.data-modul.com/sites/default/files/products/G101ICE-L01-C2-specification-12042389.pdf Fixes: 1e29b840af9f ("drm/panel: simple: Add Innolux G101ICE-L01 panel") Signed-off-by: Marek Vasut <marex@denx.de> Reviewed-by: Neil Armstrong <neil.armstrong@linaro.org> Link: https://patchwork.freedesktop.org/patch/msgid/20231008223256.279196-1-marex@denx.de
This commit is contained in:
parent
06fc41b09c
commit
3f9a91b6c0
@ -2379,13 +2379,13 @@ static const struct panel_desc innolux_g070y2_t02 = {
|
||||
static const struct display_timing innolux_g101ice_l01_timing = {
|
||||
.pixelclock = { 60400000, 71100000, 74700000 },
|
||||
.hactive = { 1280, 1280, 1280 },
|
||||
.hfront_porch = { 41, 80, 100 },
|
||||
.hback_porch = { 40, 79, 99 },
|
||||
.hsync_len = { 1, 1, 1 },
|
||||
.hfront_porch = { 30, 60, 70 },
|
||||
.hback_porch = { 30, 60, 70 },
|
||||
.hsync_len = { 22, 40, 60 },
|
||||
.vactive = { 800, 800, 800 },
|
||||
.vfront_porch = { 5, 11, 14 },
|
||||
.vback_porch = { 4, 11, 14 },
|
||||
.vsync_len = { 1, 1, 1 },
|
||||
.vfront_porch = { 3, 8, 14 },
|
||||
.vback_porch = { 3, 8, 14 },
|
||||
.vsync_len = { 4, 7, 12 },
|
||||
.flags = DISPLAY_FLAGS_DE_HIGH,
|
||||
};
|
||||
|
||||
|