md/raid5: Allow degraded raid6 to do rmw
Degraded raid6 always do reconstruct-write now. With raid6 xor supported, we can do rmw in degraded raid6. This patch can reduce many read IOs to improve performance. If the failed disk is P, Q or the disk we want to write to, we may need to do reconstruct-write in max degraded raid6. In this situation we can not read enough data from handle_stripe_dirtying() so we have to set force_rcw in handle_stripe_fill() to read all data. Reviewed-by: Alex Wu <alexwu@synology.com> Reviewed-by: BingJing Chang <bingjingc@synology.com> Reviewed-by: Danny Shih <dannyshih@synology.com> Signed-off-by: ChangSyun Peng <allenpeng@synology.com> Signed-off-by: Song Liu <songliubraving@fb.com>
This commit is contained in:
parent
a1c6ae3d9f
commit
45a4d8fd6c
@ -3557,6 +3557,7 @@ static int need_this_block(struct stripe_head *sh, struct stripe_head_state *s,
|
||||
struct r5dev *fdev[2] = { &sh->dev[s->failed_num[0]],
|
||||
&sh->dev[s->failed_num[1]] };
|
||||
int i;
|
||||
bool force_rcw = (sh->raid_conf->rmw_level == PARITY_DISABLE_RMW);
|
||||
|
||||
|
||||
if (test_bit(R5_LOCKED, &dev->flags) ||
|
||||
@ -3615,18 +3616,27 @@ static int need_this_block(struct stripe_head *sh, struct stripe_head_state *s,
|
||||
* devices must be read.
|
||||
*/
|
||||
return 1;
|
||||
|
||||
if (s->failed >= 2 &&
|
||||
(fdev[i]->towrite ||
|
||||
s->failed_num[i] == sh->pd_idx ||
|
||||
s->failed_num[i] == sh->qd_idx) &&
|
||||
!test_bit(R5_UPTODATE, &fdev[i]->flags))
|
||||
/* In max degraded raid6, If the failed disk is P, Q,
|
||||
* or we want to read the failed disk, we need to do
|
||||
* reconstruct-write.
|
||||
*/
|
||||
force_rcw = true;
|
||||
}
|
||||
|
||||
/* If we are forced to do a reconstruct-write, either because
|
||||
* the current RAID6 implementation only supports that, or
|
||||
* because parity cannot be trusted and we are currently
|
||||
* recovering it, there is extra need to be careful.
|
||||
/* If we are forced to do a reconstruct-write, because parity
|
||||
* cannot be trusted and we are currently recovering it, there
|
||||
* is extra need to be careful.
|
||||
* If one of the devices that we would need to read, because
|
||||
* it is not being overwritten (and maybe not written at all)
|
||||
* is missing/faulty, then we need to read everything we can.
|
||||
*/
|
||||
if (sh->raid_conf->level != 6 &&
|
||||
sh->raid_conf->rmw_level != PARITY_DISABLE_RMW &&
|
||||
if (!force_rcw &&
|
||||
sh->sector < sh->raid_conf->mddev->recovery_cp)
|
||||
/* reconstruct-write isn't being forced */
|
||||
return 0;
|
||||
|