regulator: pwm-regulator: Add support for continuous-voltage
The current version of PWM regulator only supports a static table approach, where pre-calculated values are supplied by the vendor and obtained via DT. The continuous-voltage method takes min_uV and max_uV, and divides the difference between them up into a number of slices. The number of slices depend on how large the duty cycle register is. This information is provided by a DT property. As the name alludes, this provides values for a continuous voltage range between min_uV and max_uV, which has obvious benefits over either limited voltage possibilities, or the requirement to provide a large voltage-table. Signed-off-by: Lee Jones <lee.jones@linaro.org> Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
parent
02258b8bcb
commit
4773be185a
@ -10,6 +10,7 @@
|
||||
* published by the Free Software Foundation.
|
||||
*/
|
||||
|
||||
#include <linux/delay.h>
|
||||
#include <linux/module.h>
|
||||
#include <linux/init.h>
|
||||
#include <linux/err.h>
|
||||
@ -21,9 +22,16 @@
|
||||
#include <linux/pwm.h>
|
||||
|
||||
struct pwm_regulator_data {
|
||||
struct pwm_voltages *duty_cycle_table;
|
||||
/* Shared */
|
||||
struct pwm_device *pwm;
|
||||
|
||||
/* Voltage table */
|
||||
struct pwm_voltages *duty_cycle_table;
|
||||
int state;
|
||||
|
||||
/* Continuous voltage */
|
||||
u32 max_duty_cycle;
|
||||
int volt_uV;
|
||||
};
|
||||
|
||||
struct pwm_voltages {
|
||||
@ -31,6 +39,9 @@ struct pwm_voltages {
|
||||
unsigned int dutycycle;
|
||||
};
|
||||
|
||||
/**
|
||||
* Voltage table call-backs
|
||||
*/
|
||||
static int pwm_regulator_get_voltage_sel(struct regulator_dev *rdev)
|
||||
{
|
||||
struct pwm_regulator_data *drvdata = rdev_get_drvdata(rdev);
|
||||
@ -78,6 +89,71 @@ static int pwm_regulator_list_voltage(struct regulator_dev *rdev,
|
||||
|
||||
return drvdata->duty_cycle_table[selector].uV;
|
||||
}
|
||||
|
||||
/**
|
||||
* Continuous voltage call-backs
|
||||
*/
|
||||
static int pwm_voltage_to_duty_cycle(struct regulator_dev *rdev,
|
||||
int volt_mV)
|
||||
{
|
||||
struct pwm_regulator_data *drvdata = rdev_get_drvdata(rdev);
|
||||
int min_mV = rdev->constraints->min_uV / 1000;
|
||||
int max_mV = rdev->constraints->max_uV / 1000;
|
||||
int max_duty_cycle = drvdata->max_duty_cycle;
|
||||
int vdiff = min_mV - max_mV;
|
||||
int pwm_code;
|
||||
int tmp;
|
||||
|
||||
tmp = ((max_duty_cycle - min_mV) * max_duty_cycle) / vdiff;
|
||||
pwm_code = ((tmp + max_duty_cycle) * volt_mV) / vdiff;
|
||||
|
||||
if (pwm_code < 0)
|
||||
pwm_code = 0;
|
||||
if (pwm_code > max_duty_cycle)
|
||||
pwm_code = max_duty_cycle;
|
||||
|
||||
return pwm_code * 100 / max_duty_cycle;
|
||||
}
|
||||
|
||||
static int pwm_regulator_get_voltage(struct regulator_dev *rdev)
|
||||
{
|
||||
struct pwm_regulator_data *drvdata = rdev_get_drvdata(rdev);
|
||||
|
||||
return drvdata->volt_uV;
|
||||
}
|
||||
|
||||
static int pwm_regulator_set_voltage(struct regulator_dev *rdev,
|
||||
int min_uV, int max_uV,
|
||||
unsigned *selector)
|
||||
{
|
||||
struct pwm_regulator_data *drvdata = rdev_get_drvdata(rdev);
|
||||
unsigned int ramp_delay = rdev->constraints->ramp_delay;
|
||||
int duty_cycle;
|
||||
int ret;
|
||||
|
||||
duty_cycle = pwm_voltage_to_duty_cycle(rdev, min_uV / 1000);
|
||||
|
||||
ret = pwm_config(drvdata->pwm,
|
||||
(drvdata->pwm->period / 100) * duty_cycle,
|
||||
drvdata->pwm->period);
|
||||
if (ret) {
|
||||
dev_err(&rdev->dev, "Failed to configure PWM\n");
|
||||
return ret;
|
||||
}
|
||||
|
||||
ret = pwm_enable(drvdata->pwm);
|
||||
if (ret) {
|
||||
dev_err(&rdev->dev, "Failed to enable PWM\n");
|
||||
return ret;
|
||||
}
|
||||
drvdata->volt_uV = min_uV;
|
||||
|
||||
/* Delay required by PWM regulator to settle to the new voltage */
|
||||
usleep_range(ramp_delay, ramp_delay + 1000);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static struct regulator_ops pwm_regulator_voltage_table_ops = {
|
||||
.set_voltage_sel = pwm_regulator_set_voltage_sel,
|
||||
.get_voltage_sel = pwm_regulator_get_voltage_sel,
|
||||
@ -85,6 +161,11 @@ static struct regulator_ops pwm_regulator_voltage_table_ops = {
|
||||
.map_voltage = regulator_map_voltage_iterate,
|
||||
};
|
||||
|
||||
static struct regulator_ops pwm_regulator_voltage_continuous_ops = {
|
||||
.get_voltage = pwm_regulator_get_voltage,
|
||||
.set_voltage = pwm_regulator_set_voltage,
|
||||
};
|
||||
|
||||
static struct regulator_desc pwm_regulator_desc = {
|
||||
.name = "pwm-regulator",
|
||||
.type = REGULATOR_VOLTAGE,
|
||||
@ -129,6 +210,25 @@ static int pwm_regulator_init_table(struct platform_device *pdev,
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int pwm_regulator_init_continuous(struct platform_device *pdev,
|
||||
struct pwm_regulator_data *drvdata)
|
||||
{
|
||||
struct device_node *np = pdev->dev.of_node;
|
||||
int ret;
|
||||
|
||||
ret = of_property_read_u32(np, "max-duty-cycle",
|
||||
&drvdata->max_duty_cycle);
|
||||
if (ret) {
|
||||
dev_err(&pdev->dev, "Failed to read \"pwm-max-value\"\n");
|
||||
return ret;
|
||||
}
|
||||
|
||||
pwm_regulator_desc.ops = &pwm_regulator_voltage_continuous_ops;
|
||||
pwm_regulator_desc.continuous_voltage_range = true;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int pwm_regulator_probe(struct platform_device *pdev)
|
||||
{
|
||||
struct pwm_regulator_data *drvdata;
|
||||
@ -146,14 +246,12 @@ static int pwm_regulator_probe(struct platform_device *pdev)
|
||||
if (!drvdata)
|
||||
return -ENOMEM;
|
||||
|
||||
if (of_find_property(np, "voltage-table", NULL)) {
|
||||
if (of_find_property(np, "voltage-table", NULL))
|
||||
ret = pwm_regulator_init_table(pdev, drvdata);
|
||||
if (ret)
|
||||
return ret;
|
||||
} else {
|
||||
dev_err(&pdev->dev, "No \"voltage-table\" supplied\n");
|
||||
return -EINVAL;
|
||||
}
|
||||
else
|
||||
ret = pwm_regulator_init_continuous(pdev, drvdata);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
config.init_data = of_get_regulator_init_data(&pdev->dev, np,
|
||||
&pwm_regulator_desc);
|
||||
|
Loading…