drm/msm/dp: use dp_ctrl_off_link_stream during PHY compliance test run
DP cable should always connect to DPU during the entire PHY compliance testing run. Since DP PHY compliance test is executed at irq_hpd event context, dp_ctrl_off_link_stream() should be used instead of dp_ctrl_off(). dp_ctrl_off() is used for unplug event which is triggered when DP cable is dis connected. Changes in V2: -- add fixes statement Fixes: f21c8a276c2d ("drm/msm/dp: handle irq_hpd with sink_count = 0 correctly") Signed-off-by: Kuogee Hsieh <khsieh@codeaurora.org> Reviewed-by: Stephen Boyd <swboyd@chromium.org> Link: https://lore.kernel.org/r/1628196295-7382-2-git-send-email-khsieh@codeaurora.org Signed-off-by: Rob Clark <robdclark@chromium.org>
This commit is contained in:
parent
6977cc89c8
commit
52352fe2f8
@ -1529,7 +1529,7 @@ static int dp_ctrl_process_phy_test_request(struct dp_ctrl_private *ctrl)
|
||||
* running. Add the global reset just before disabling the
|
||||
* link clocks and core clocks.
|
||||
*/
|
||||
ret = dp_ctrl_off(&ctrl->dp_ctrl);
|
||||
ret = dp_ctrl_off_link_stream(&ctrl->dp_ctrl);
|
||||
if (ret) {
|
||||
DRM_ERROR("failed to disable DP controller\n");
|
||||
return ret;
|
||||
|
Loading…
x
Reference in New Issue
Block a user