regulator: core: Handle fixed voltage in map_voltage_linear
Fixed voltage is a kind of linear mapping where n_voltages is 1. This change allows [list|map]_voltage_linear to be used for fixed voltage. For fixed voltage, n_voltages is 1 and the only valid selector is 0. Thus we actually don't care the uV_step setting. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
parent
93b07e7bcd
commit
5a6881e8e1
@ -2070,6 +2070,14 @@ int regulator_map_voltage_linear(struct regulator_dev *rdev,
|
||||
{
|
||||
int ret, voltage;
|
||||
|
||||
/* Allow uV_step to be 0 for fixed voltage */
|
||||
if (rdev->desc->n_voltages == 1 && rdev->desc->uV_step == 0) {
|
||||
if (min_uV <= rdev->desc->min_uV && rdev->desc->min_uV <= max_uV)
|
||||
return 0;
|
||||
else
|
||||
return -EINVAL;
|
||||
}
|
||||
|
||||
if (!rdev->desc->uV_step) {
|
||||
BUG_ON(!rdev->desc->uV_step);
|
||||
return -EINVAL;
|
||||
|
Loading…
Reference in New Issue
Block a user