powerpc/tau: Use appropriate temperature sample interval

According to the MPC750 Users Manual, the SITV value in Thermal
Management Register 3 is 13 bits long. The present code calculates the
SITV value as 60 * 500 cycles. This would overflow to give 10 us on
a 500 MHz CPU rather than the intended 60 us. (But according to the
Microprocessor Datasheet, there is also a factor of 266 that has to be
applied to this value on certain parts i.e. speed sort above 266 MHz.)
Always use the maximum cycle count, as recommended by the Datasheet.

Fixes: 1da177e4c3 ("Linux-2.6.12-rc2")
Signed-off-by: Finn Thain <fthain@telegraphics.com.au>
Tested-by: Stan Johnson <userm57@yahoo.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Link: https://lore.kernel.org/r/896f542e5f0f1d6cf8218524c2b67d79f3d69b3c.1599260540.git.fthain@telegraphics.com.au
This commit is contained in:
Finn Thain
2020-09-05 09:02:20 +10:00
committed by Michael Ellerman
parent b32d5d7e92
commit 66943005cc
2 changed files with 5 additions and 9 deletions

View File

@ -817,7 +817,7 @@
#define THRM1_TIN (1 << 31)
#define THRM1_TIV (1 << 30)
#define THRM1_THRES(x) ((x&0x7f)<<23)
#define THRM3_SITV(x) ((x&0x3fff)<<1)
#define THRM3_SITV(x) ((x & 0x1fff) << 1)
#define THRM1_TID (1<<2)
#define THRM1_TIE (1<<1)
#define THRM1_V (1<<0)