regulator: core: print error value when constraints are not applied
With commit 064d5cd110
(regulator: core: Fix the init of DT defined fixed regulators)
We ensure that regulator must be capable of providing it's current
voltage when constraints are used, however adding the return value in
the print is a little more informative to explain the nature of the
failure involved.
So, instead of providing message such as:
smps9: failed to get the current voltage
having error value added to the message such as:
smps9: failed to get the current voltage(-22)
is a little more informative for debugging the error.
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
This commit is contained in:
parent
978371cbab
commit
69d588392b
@ -846,7 +846,9 @@ static int machine_constraints_voltage(struct regulator_dev *rdev,
|
||||
rdev->constraints->min_uV == rdev->constraints->max_uV) {
|
||||
int current_uV = _regulator_get_voltage(rdev);
|
||||
if (current_uV < 0) {
|
||||
rdev_err(rdev, "failed to get the current voltage\n");
|
||||
rdev_err(rdev,
|
||||
"failed to get the current voltage(%d)\n",
|
||||
current_uV);
|
||||
return current_uV;
|
||||
}
|
||||
if (current_uV < rdev->constraints->min_uV ||
|
||||
@ -856,8 +858,8 @@ static int machine_constraints_voltage(struct regulator_dev *rdev,
|
||||
rdev->constraints->max_uV);
|
||||
if (ret < 0) {
|
||||
rdev_err(rdev,
|
||||
"failed to apply %duV constraint\n",
|
||||
rdev->constraints->min_uV);
|
||||
"failed to apply %duV constraint(%d)\n",
|
||||
rdev->constraints->min_uV, ret);
|
||||
return ret;
|
||||
}
|
||||
}
|
||||
|
Loading…
Reference in New Issue
Block a user