mfd: da9063: Fix OTP control register names to match datasheets for DA9063/63L
Mismatch between what is found in the Datasheets for DA9063 and DA9063L provided by Dialog Semiconductor, and the register names provided in the MFD registers file. The changes are for the OTP (one-time-programming) control registers. The two naming errors are OPT instead of OTP, and COUNT instead of CONT (i.e. control). Cc: Stable <stable@vger.kernel.org> Signed-off-by: Steve Twiss <stwiss.opensource@diasemi.com> Signed-off-by: Lee Jones <lee.jones@linaro.org>
This commit is contained in:
parent
9e364e87ad
commit
6b4814a945
@ -210,9 +210,9 @@
|
||||
|
||||
/* DA9063 Configuration registers */
|
||||
/* OTP */
|
||||
#define DA9063_REG_OPT_COUNT 0x101
|
||||
#define DA9063_REG_OPT_ADDR 0x102
|
||||
#define DA9063_REG_OPT_DATA 0x103
|
||||
#define DA9063_REG_OTP_CONT 0x101
|
||||
#define DA9063_REG_OTP_ADDR 0x102
|
||||
#define DA9063_REG_OTP_DATA 0x103
|
||||
|
||||
/* Customer Trim and Configuration */
|
||||
#define DA9063_REG_T_OFFSET 0x104
|
||||
|
Loading…