mfd: rave-sp: Initialize flow control and parity of the port
Relying on serial port defaults for flow control and parity can result in complete breakdown of communication with RAVE SP on some platforms where defaults are not what we need them to be. One such case is VF610-base ZII SPU3 board (not supported upstream). To avoid this problem in the future, add code to explicitly configure both. Signed-off-by: Andrey Smirnov <andrew.smirnov@gmail.com> Signed-off-by: Lee Jones <lee.jones@linaro.org>
This commit is contained in:
parent
a6e3bb0288
commit
6c450bdf13
@ -766,6 +766,13 @@ static int rave_sp_probe(struct serdev_device *serdev)
|
||||
return ret;
|
||||
|
||||
serdev_device_set_baudrate(serdev, baud);
|
||||
serdev_device_set_flow_control(serdev, false);
|
||||
|
||||
ret = serdev_device_set_parity(serdev, SERDEV_PARITY_NONE);
|
||||
if (ret) {
|
||||
dev_err(dev, "Failed to set parity\n");
|
||||
return ret;
|
||||
}
|
||||
|
||||
ret = rave_sp_get_status(sp);
|
||||
if (ret) {
|
||||
|
Loading…
Reference in New Issue