acerhdf: return temperature in milidegree instead of degree
Return temperature in milidegree instead of degree, as sysfs-api requires the temperature in milidegree. Signed-off-by: Peter Feuerer <peter@piie.net> Tested-by: Borislav Petkov <petkovbb@gmail.com> Cc: Andreas Mohr <andi@lisas.de> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Len Brown <len.brown@intel.com>
This commit is contained in:
parent
a8a8a669ea
commit
7005291706
@ -52,7 +52,7 @@
|
||||
*/
|
||||
#undef START_IN_KERNEL_MODE
|
||||
|
||||
#define DRV_VER "0.5.17"
|
||||
#define DRV_VER "0.5.18"
|
||||
|
||||
/*
|
||||
* According to the Atom N270 datasheet,
|
||||
@ -61,7 +61,7 @@
|
||||
* measured by the on-die thermal monitor are within 0 <= Tj <= 90. So,
|
||||
* assume 89°C is critical temperature.
|
||||
*/
|
||||
#define ACERHDF_TEMP_CRIT 89
|
||||
#define ACERHDF_TEMP_CRIT 89000
|
||||
#define ACERHDF_FAN_OFF 0
|
||||
#define ACERHDF_FAN_AUTO 1
|
||||
|
||||
@ -69,7 +69,7 @@
|
||||
* No matter what value the user puts into the fanon variable, turn on the fan
|
||||
* at 80 degree Celsius to prevent hardware damage
|
||||
*/
|
||||
#define ACERHDF_MAX_FANON 80
|
||||
#define ACERHDF_MAX_FANON 80000
|
||||
|
||||
/*
|
||||
* Maximum interval between two temperature checks is 15 seconds, as the die
|
||||
@ -85,8 +85,8 @@ static int kernelmode;
|
||||
#endif
|
||||
|
||||
static unsigned int interval = 10;
|
||||
static unsigned int fanon = 63;
|
||||
static unsigned int fanoff = 58;
|
||||
static unsigned int fanon = 63000;
|
||||
static unsigned int fanoff = 58000;
|
||||
static unsigned int verbose;
|
||||
static unsigned int fanstate = ACERHDF_FAN_AUTO;
|
||||
static char force_bios[16];
|
||||
@ -171,7 +171,7 @@ static int acerhdf_get_temp(int *temp)
|
||||
if (ec_read(bios_cfg->tempreg, &read_temp))
|
||||
return -EINVAL;
|
||||
|
||||
*temp = read_temp;
|
||||
*temp = read_temp * 1000;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
Loading…