power_supply: bq24735: Convert to using managed resources
Use managed resource functions like devm_kasprintf and devm_power_supply_register in bq24735_charger_probe. To be compatible with the change, replace various gotos by direct returns and drop unneeded labels. Also, remove bq24735_charger_remove as it is now redundant. Signed-off-by: Vaishali Thakkar <vthakkar1994@gmail.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
This commit is contained in:
parent
3309aa4941
commit
71a5a50843
@ -267,8 +267,9 @@ static int bq24735_charger_probe(struct i2c_client *client,
|
||||
|
||||
name = (char *)charger->pdata->name;
|
||||
if (!name) {
|
||||
name = kasprintf(GFP_KERNEL, "bq24735@%s",
|
||||
dev_name(&client->dev));
|
||||
name = devm_kasprintf(&client->dev, GFP_KERNEL,
|
||||
"bq24735@%s",
|
||||
dev_name(&client->dev));
|
||||
if (!name) {
|
||||
dev_err(&client->dev, "Failed to alloc device name\n");
|
||||
return -ENOMEM;
|
||||
@ -296,23 +297,21 @@ static int bq24735_charger_probe(struct i2c_client *client,
|
||||
if (ret < 0) {
|
||||
dev_err(&client->dev, "Failed to read manufacturer id : %d\n",
|
||||
ret);
|
||||
goto err_free_name;
|
||||
return ret;
|
||||
} else if (ret != 0x0040) {
|
||||
dev_err(&client->dev,
|
||||
"manufacturer id mismatch. 0x0040 != 0x%04x\n", ret);
|
||||
ret = -ENODEV;
|
||||
goto err_free_name;
|
||||
return -ENODEV;
|
||||
}
|
||||
|
||||
ret = bq24735_read_word(client, BQ24735_DEVICE_ID);
|
||||
if (ret < 0) {
|
||||
dev_err(&client->dev, "Failed to read device id : %d\n", ret);
|
||||
goto err_free_name;
|
||||
return ret;
|
||||
} else if (ret != 0x000B) {
|
||||
dev_err(&client->dev,
|
||||
"device id mismatch. 0x000b != 0x%04x\n", ret);
|
||||
ret = -ENODEV;
|
||||
goto err_free_name;
|
||||
return -ENODEV;
|
||||
}
|
||||
|
||||
if (gpio_is_valid(charger->pdata->status_gpio)) {
|
||||
@ -331,7 +330,7 @@ static int bq24735_charger_probe(struct i2c_client *client,
|
||||
ret = bq24735_config_charger(charger);
|
||||
if (ret < 0) {
|
||||
dev_err(&client->dev, "failed in configuring charger");
|
||||
goto err_free_name;
|
||||
return ret;
|
||||
}
|
||||
|
||||
/* check for AC adapter presence */
|
||||
@ -339,17 +338,17 @@ static int bq24735_charger_probe(struct i2c_client *client,
|
||||
ret = bq24735_enable_charging(charger);
|
||||
if (ret < 0) {
|
||||
dev_err(&client->dev, "Failed to enable charging\n");
|
||||
goto err_free_name;
|
||||
return ret;
|
||||
}
|
||||
}
|
||||
|
||||
charger->charger = power_supply_register(&client->dev, supply_desc,
|
||||
&psy_cfg);
|
||||
charger->charger = devm_power_supply_register(&client->dev, supply_desc,
|
||||
&psy_cfg);
|
||||
if (IS_ERR(charger->charger)) {
|
||||
ret = PTR_ERR(charger->charger);
|
||||
dev_err(&client->dev, "Failed to register power supply: %d\n",
|
||||
ret);
|
||||
goto err_free_name;
|
||||
return ret;
|
||||
}
|
||||
|
||||
if (client->irq) {
|
||||
@ -364,33 +363,10 @@ static int bq24735_charger_probe(struct i2c_client *client,
|
||||
dev_err(&client->dev,
|
||||
"Unable to register IRQ %d err %d\n",
|
||||
client->irq, ret);
|
||||
goto err_unregister_supply;
|
||||
return ret;
|
||||
}
|
||||
}
|
||||
|
||||
return 0;
|
||||
err_unregister_supply:
|
||||
power_supply_unregister(charger->charger);
|
||||
err_free_name:
|
||||
if (name != charger->pdata->name)
|
||||
kfree(name);
|
||||
|
||||
return ret;
|
||||
}
|
||||
|
||||
static int bq24735_charger_remove(struct i2c_client *client)
|
||||
{
|
||||
struct bq24735 *charger = i2c_get_clientdata(client);
|
||||
|
||||
if (charger->client->irq)
|
||||
devm_free_irq(&charger->client->dev, charger->client->irq,
|
||||
&charger->charger);
|
||||
|
||||
power_supply_unregister(charger->charger);
|
||||
|
||||
if (charger->charger_desc.name != charger->pdata->name)
|
||||
kfree(charger->charger_desc.name);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
@ -412,7 +388,6 @@ static struct i2c_driver bq24735_charger_driver = {
|
||||
.of_match_table = bq24735_match_ids,
|
||||
},
|
||||
.probe = bq24735_charger_probe,
|
||||
.remove = bq24735_charger_remove,
|
||||
.id_table = bq24735_charger_id,
|
||||
};
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user