diff --git a/Documentation/devicetree/bindings/regulator/regulator.yaml b/Documentation/devicetree/bindings/regulator/regulator.yaml index 5b8d55f7c43b..1ef380d1515e 100644 --- a/Documentation/devicetree/bindings/regulator/regulator.yaml +++ b/Documentation/devicetree/bindings/regulator/regulator.yaml @@ -186,6 +186,14 @@ properties: be enabled but limit setting can be omitted. Limit is given as microvolt offset from voltage set to regulator. + regulator-uv-less-critical-window-ms: + description: Specifies the time window (in milliseconds) following a + critical under-voltage event during which the system can continue to + operate safely while performing less critical operations. This property + provides a defined duration before a more severe reaction to the + under-voltage event is needed, allowing for certain non-urgent actions to + be carried out in preparation for potential power loss. + regulator-temp-protection-kelvin: description: Set over temperature protection limit. This is a limit where hardware performs emergency shutdown. Zero can be passed to disable