dt-bindings: iio: pressure: honeywell,mprls0025pa.yaml improvements
Define enum inside the honeywell,transfer-function property block. Set the correct irq edge in the example block. Based on the datasheet, in table 13 on page 11: "End-of-conversion indicator: This pin is set high when a measurement and calculation have been completed and the data is ready to be clocked out" Add description on End-of-conversion interrupt. Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> Co-developed-by: Andreas Klinger <ak@it-klinger.de> Signed-off-by: Andreas Klinger <ak@it-klinger.de> Signed-off-by: Petre Rodan <petre.rodan@subdimension.ro> Link: https://lore.kernel.org/r/20231229092445.30180-2-petre.rodan@subdimension.ro Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
0ba6014a23
commit
7b34e1e330
@ -42,6 +42,10 @@ properties:
|
||||
maxItems: 1
|
||||
|
||||
interrupts:
|
||||
description:
|
||||
Optional interrupt for indicating End-of-conversion.
|
||||
If not present, the driver loops for a while until the received status
|
||||
byte indicates correct measurement.
|
||||
maxItems: 1
|
||||
|
||||
reset-gpios:
|
||||
@ -65,6 +69,7 @@ properties:
|
||||
1 - A, 10% to 90% of 2^24 (1677722 .. 15099494)
|
||||
2 - B, 2.5% to 22.5% of 2^24 (419430 .. 3774874)
|
||||
3 - C, 20% to 80% of 2^24 (3355443 .. 13421773)
|
||||
enum: [1, 2, 3]
|
||||
$ref: /schemas/types.yaml#/definitions/uint32
|
||||
|
||||
vdd-supply:
|
||||
@ -93,7 +98,7 @@ examples:
|
||||
reg = <0x18>;
|
||||
reset-gpios = <&gpio3 19 GPIO_ACTIVE_HIGH>;
|
||||
interrupt-parent = <&gpio3>;
|
||||
interrupts = <21 IRQ_TYPE_EDGE_FALLING>;
|
||||
interrupts = <21 IRQ_TYPE_EDGE_RISING>;
|
||||
honeywell,pmin-pascal = <0>;
|
||||
honeywell,pmax-pascal = <172369>;
|
||||
honeywell,transfer-function = <1>;
|
||||
|