thermal: Do not log an error if thermal_zone_get_temp returns -EAGAIN
Some temperature sensors only get updated every few seconds and while waiting for the first irq reporting a (new) temperature to happen there get_temp operand will return -EAGAIN as it does not have any data to report yet. Not logging an error in this case avoids messages like these from showing up in dmesg on affected systems: [ 1.219353] thermal thermal_zone0: failed to read out thermal zone 0 [ 2.015433] thermal thermal_zone0: failed to read out thermal zone 0 [ 2.416737] thermal thermal_zone0: failed to read out thermal zone 0 Reviewed-by: Dmitry Torokhov <dmitry.torokhov@gmail.com> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
2771d00081
commit
7e497a7375
@ -458,8 +458,10 @@ static void update_temperature(struct thermal_zone_device *tz)
|
||||
|
||||
ret = thermal_zone_get_temp(tz, &temp);
|
||||
if (ret) {
|
||||
dev_warn(&tz->device, "failed to read out thermal zone %d\n",
|
||||
tz->id);
|
||||
if (ret != -EAGAIN)
|
||||
dev_warn(&tz->device,
|
||||
"failed to read out thermal zone (%d)\n",
|
||||
ret);
|
||||
return;
|
||||
}
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user