clocksource: samsung_pwm_timer: Work around rounding errors in clockevents core
Due to rounding errors in clockevents core (in conversions between ticks and nsecs), it might happen that the set_next_event callback gets called with cycles = 0, causing the code to incorrectly program the PWM timer. This patch modifies the callback to program the timer for 1 tick, if received tick count value is 0. Signed-off-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by: Arnd Bergmann <arnd@arndb.de> Acked-by: Kukjin Kim <kgene.kim@samsung.com> Signed-off-by: Olof Johansson <olof@lixom.net>
This commit is contained in:
parent
6fe4dfd041
commit
81d4f7bfdc
@ -176,6 +176,19 @@ static void samsung_time_start(unsigned int channel, bool periodic)
|
||||
static int samsung_set_next_event(unsigned long cycles,
|
||||
struct clock_event_device *evt)
|
||||
{
|
||||
/*
|
||||
* This check is needed to account for internal rounding
|
||||
* errors inside clockevents core, which might result in
|
||||
* passing cycles = 0, which in turn would not generate any
|
||||
* timer interrupt and hang the system.
|
||||
*
|
||||
* Another solution would be to set up the clockevent device
|
||||
* with min_delta = 2, but this would unnecessarily increase
|
||||
* the minimum sleep period.
|
||||
*/
|
||||
if (!cycles)
|
||||
cycles = 1;
|
||||
|
||||
samsung_time_setup(pwm.event_id, cycles);
|
||||
samsung_time_start(pwm.event_id, false);
|
||||
|
||||
|
Loading…