iio: light: as73211: use IIO_VAL_FRACTIONAL for intensity scales
The scale values associated to the light channels are calculated as a division that can be better expressed as an IIO_VAL_FRACTIONAL type instead of the current IIO_VAL_INT. Note that the constant values used for the calculation were scaled up to work with integers, turning the nW/cm^2 units from the datasheet into nW/m^2, which would not be necessary with the IIO_VAL_FRACTIONAL type. But to avoid issues from current users of the driver, the units must be kept. Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
6613476e22
commit
8745465e88
@ -356,25 +356,24 @@ static int as73211_read_raw(struct iio_dev *indio_dev, struct iio_chan_spec cons
|
||||
return IIO_VAL_INT_PLUS_MICRO;
|
||||
|
||||
case IIO_INTENSITY: {
|
||||
unsigned int scale;
|
||||
|
||||
switch (chan->channel2) {
|
||||
case IIO_MOD_X:
|
||||
scale = AS73211_SCALE_X;
|
||||
*val = AS73211_SCALE_X;
|
||||
break;
|
||||
case IIO_MOD_Y:
|
||||
scale = AS73211_SCALE_Y;
|
||||
*val = AS73211_SCALE_Y;
|
||||
break;
|
||||
case IIO_MOD_Z:
|
||||
scale = AS73211_SCALE_Z;
|
||||
*val = AS73211_SCALE_Z;
|
||||
break;
|
||||
default:
|
||||
return -EINVAL;
|
||||
}
|
||||
scale /= as73211_gain(data);
|
||||
scale /= as73211_integration_time_1024cyc(data);
|
||||
*val = scale;
|
||||
return IIO_VAL_INT;
|
||||
*val2 = as73211_integration_time_1024cyc(data) *
|
||||
as73211_gain(data);
|
||||
|
||||
return IIO_VAL_FRACTIONAL;
|
||||
|
||||
default:
|
||||
return -EINVAL;
|
||||
|
Loading…
x
Reference in New Issue
Block a user