iio: light: as73211: use IIO_VAL_FRACTIONAL for intensity scales

The scale values associated to the light channels are calculated as a
division that can be better expressed as an IIO_VAL_FRACTIONAL type
instead of the current IIO_VAL_INT.

Note that the constant values used for the calculation were scaled up to
work with integers, turning the nW/cm^2 units from the datasheet into
nW/m^2, which would not be necessary with the IIO_VAL_FRACTIONAL type.
But to avoid issues from current users of the driver, the units must be
kept.

Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Javier Carrasco 2024-01-03 13:08:51 +01:00 committed by Jonathan Cameron
parent 6613476e22
commit 8745465e88

View File

@ -356,25 +356,24 @@ static int as73211_read_raw(struct iio_dev *indio_dev, struct iio_chan_spec cons
return IIO_VAL_INT_PLUS_MICRO;
case IIO_INTENSITY: {
unsigned int scale;
switch (chan->channel2) {
case IIO_MOD_X:
scale = AS73211_SCALE_X;
*val = AS73211_SCALE_X;
break;
case IIO_MOD_Y:
scale = AS73211_SCALE_Y;
*val = AS73211_SCALE_Y;
break;
case IIO_MOD_Z:
scale = AS73211_SCALE_Z;
*val = AS73211_SCALE_Z;
break;
default:
return -EINVAL;
}
scale /= as73211_gain(data);
scale /= as73211_integration_time_1024cyc(data);
*val = scale;
return IIO_VAL_INT;
*val2 = as73211_integration_time_1024cyc(data) *
as73211_gain(data);
return IIO_VAL_FRACTIONAL;
default:
return -EINVAL;