PCI: Check only the Vendor ID to identify Configuration Request Retry

Per PCIe r3.0, sec 2.3.2, if a Root Complex

  - has Configuration Request Retry Status Software Visibility enabled,
  - issues a Configuration Read of both bytes of the Vendor ID, and
  - receives a Completion with Configuration Request Retry Status (CRS),

it must complete the request to the host by fabricating data of 0x0001 for
the Vendor ID and 0xff for any additional bytes in the request.

Linux issues a single config read for the four bytes containing the Vendor
ID and the Device ID.  Previously we checked all four bytes for 0xffff0001
to identify CRS.

However, it is only the Vendor ID that really indicates CRS, because it's
sufficient to read only those two bytes.  Checking the Device ID verifies
spec compliance but doesn't add any information.

Some Root Complexes appear to indicate CRS by returning 0x0001 for the
Vendor ID along with the actual the Device ID.  Previously we interpreted
that as a valid Vendor/Device ID pair, although 0x0001 is reserved and
cannot be a valid Vendor ID.

[bhelgaas: changelog]
Link: http://lkml.kernel.org/r/4729FC36.3040000@gmail.com
Signed-off-by: Rajat Jain <rajatxjain@gmail.com>
Signed-off-by: Rajat Jain <rajatjain@juniper.net>
Signed-off-by: Guenter Roeck <groeck@juniper.net>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
This commit is contained in:
Rajat Jain 2014-09-08 14:19:49 -07:00 committed by Bjorn Helgaas
parent 52addcf9d6
commit 89665a6a71

View File

@ -1292,8 +1292,13 @@ bool pci_bus_read_dev_vendor_id(struct pci_bus *bus, int devfn, u32 *l,
*l == 0x0000ffff || *l == 0xffff0000)
return false;
/* Configuration request Retry Status */
while (*l == 0xffff0001) {
/*
* Configuration Request Retry Status. Some root ports return the
* actual device ID instead of the synthetic ID (0xFFFF) required
* by the PCIe spec. Ignore the device ID and only check for
* (vendor id == 1).
*/
while ((*l & 0xffff) == 0x0001) {
if (!crs_timeout)
return false;