bnxt_en: Log unknown link speed appropriately.
If the VF virtual link is set to always enabled, the speed may be unknown when the physical link is down. The driver currently logs the link speed as 4294967295 Mbps which is SPEED_UNKNOWN. Modify the link up log message as "speed unknown" which makes more sense. Reviewed-by: Vasundhara Volam <vasundhara-v.volam@broadcom.com> Reviewed-by: Edwin Peer <edwin.peer@broadcom.com> Signed-off-by: Michael Chan <michael.chan@broadcom.com> Link: https://lore.kernel.org/r/1602493854-29283-7-git-send-email-michael.chan@broadcom.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
This commit is contained in:
parent
c966c67c09
commit
8eddb3e7ce
@ -8902,6 +8902,11 @@ static void bnxt_report_link(struct bnxt *bp)
|
||||
u16 fec;
|
||||
|
||||
netif_carrier_on(bp->dev);
|
||||
speed = bnxt_fw_to_ethtool_speed(bp->link_info.link_speed);
|
||||
if (speed == SPEED_UNKNOWN) {
|
||||
netdev_info(bp->dev, "NIC Link is Up, speed unknown\n");
|
||||
return;
|
||||
}
|
||||
if (bp->link_info.duplex == BNXT_LINK_DUPLEX_FULL)
|
||||
duplex = "full";
|
||||
else
|
||||
@ -8914,7 +8919,6 @@ static void bnxt_report_link(struct bnxt *bp)
|
||||
flow_ctrl = "ON - receive";
|
||||
else
|
||||
flow_ctrl = "none";
|
||||
speed = bnxt_fw_to_ethtool_speed(bp->link_info.link_speed);
|
||||
netdev_info(bp->dev, "NIC Link is Up, %u Mbps %s duplex, Flow control: %s\n",
|
||||
speed, duplex, flow_ctrl);
|
||||
if (bp->flags & BNXT_FLAG_EEE_CAP)
|
||||
|
Loading…
x
Reference in New Issue
Block a user