arm64: dts: meson: g12a: add cooling properties
Add missing #colling-cells field for G12A SoC Add cooling-map for passive and hot trip point Tested-by: Christian Hewitt <christianshewitt@gmail.com> Tested-by: Kevin Hilman <khilman@baylibre.com> Reviewed-by: Neil Armstrong <narmstrong@baylibre.com> Reviewed-by: Amit Kucheria <amit.kucheria@linaro.org> Signed-off-by: Guillaume La Roque <glaroque@baylibre.com> Signed-off-by: Kevin Hilman <khilman@baylibre.com>
This commit is contained in:
parent
e7251ed74e
commit
8eef8bca12
@ -18,6 +18,7 @@
|
||||
reg = <0x0 0x0>;
|
||||
enable-method = "psci";
|
||||
next-level-cache = <&l2>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu1: cpu@1 {
|
||||
@ -26,6 +27,7 @@
|
||||
reg = <0x0 0x1>;
|
||||
enable-method = "psci";
|
||||
next-level-cache = <&l2>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu2: cpu@2 {
|
||||
@ -34,6 +36,7 @@
|
||||
reg = <0x0 0x2>;
|
||||
enable-method = "psci";
|
||||
next-level-cache = <&l2>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu3: cpu@3 {
|
||||
@ -42,6 +45,7 @@
|
||||
reg = <0x0 0x3>;
|
||||
enable-method = "psci";
|
||||
next-level-cache = <&l2>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
l2: l2-cache0 {
|
||||
@ -109,3 +113,23 @@
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
&cpu_thermal {
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&cpu_passive>;
|
||||
cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
};
|
||||
|
||||
map1 {
|
||||
trip = <&cpu_hot>;
|
||||
cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
Loading…