hwmon: (lm90) Only re-read registers if volatile
When reading 16-bit volatile registers, the code uses a trick to determine if a temperature is consistent: It reads the high part of the register twice. If the values are the same, the code assumes that the reading is consistent. If the value differs, the code re-reads the second register as well and assumes that it now has correct values. This is only necessary for volatile registers. Add a parameter to lm90_read16() to indicate if the register is volatile to avoid the extra overhead for non-volatile registers. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
b2644494a4
commit
8f19501d87
@ -602,29 +602,34 @@ static int lm90_write_reg(struct i2c_client *client, u8 reg, u8 val)
|
||||
return i2c_smbus_write_byte_data(client, lm90_write_reg_addr(reg), val);
|
||||
}
|
||||
|
||||
static int lm90_read16(struct i2c_client *client, u8 regh, u8 regl)
|
||||
static int lm90_read16(struct i2c_client *client, u8 regh, u8 regl,
|
||||
bool is_volatile)
|
||||
{
|
||||
int oldh, newh, l;
|
||||
|
||||
/*
|
||||
* There is a trick here. We have to read two registers to have the
|
||||
* sensor temperature, but we have to beware a conversion could occur
|
||||
* between the readings. The datasheet says we should either use
|
||||
* the one-shot conversion register, which we don't want to do
|
||||
* (disables hardware monitoring) or monitor the busy bit, which is
|
||||
* impossible (we can't read the values and monitor that bit at the
|
||||
* exact same time). So the solution used here is to read the high
|
||||
* byte once, then the low byte, then the high byte again. If the new
|
||||
* high byte matches the old one, then we have a valid reading. Else
|
||||
* we have to read the low byte again, and now we believe we have a
|
||||
* correct reading.
|
||||
*/
|
||||
oldh = lm90_read_reg(client, regh);
|
||||
if (oldh < 0)
|
||||
return oldh;
|
||||
l = lm90_read_reg(client, regl);
|
||||
if (l < 0)
|
||||
return l;
|
||||
|
||||
if (!is_volatile)
|
||||
return (oldh << 8) | l;
|
||||
|
||||
/*
|
||||
* For volatile registers we have to use a trick.
|
||||
* We have to read two registers to have the sensor temperature,
|
||||
* but we have to beware a conversion could occur between the
|
||||
* readings. The datasheet says we should either use
|
||||
* the one-shot conversion register, which we don't want to do
|
||||
* (disables hardware monitoring) or monitor the busy bit, which is
|
||||
* impossible (we can't read the values and monitor that bit at the
|
||||
* exact same time). So the solution used here is to read the high
|
||||
* the high byte again. If the new high byte matches the old one,
|
||||
* then we have a valid reading. Otherwise we have to read the low
|
||||
* byte again, and now we believe we have a correct reading.
|
||||
*/
|
||||
newh = lm90_read_reg(client, regh);
|
||||
if (newh < 0)
|
||||
return newh;
|
||||
@ -766,7 +771,7 @@ static int lm90_update_limits(struct device *dev)
|
||||
|
||||
if (data->flags & LM90_HAVE_OFFSET) {
|
||||
val = lm90_read16(client, LM90_REG_REMOTE_OFFSH,
|
||||
LM90_REG_REMOTE_OFFSL);
|
||||
LM90_REG_REMOTE_OFFSL, false);
|
||||
if (val < 0)
|
||||
return val;
|
||||
data->temp11[REMOTE_OFFSET] = val;
|
||||
@ -999,7 +1004,7 @@ static int lm90_update_device(struct device *dev)
|
||||
|
||||
if (data->reg_local_ext) {
|
||||
val = lm90_read16(client, LM90_REG_LOCAL_TEMP,
|
||||
data->reg_local_ext);
|
||||
data->reg_local_ext, true);
|
||||
if (val < 0)
|
||||
return val;
|
||||
data->temp11[LOCAL_TEMP] = val;
|
||||
@ -1010,7 +1015,7 @@ static int lm90_update_device(struct device *dev)
|
||||
data->temp11[LOCAL_TEMP] = val << 8;
|
||||
}
|
||||
val = lm90_read16(client, LM90_REG_REMOTE_TEMPH,
|
||||
LM90_REG_REMOTE_TEMPL);
|
||||
LM90_REG_REMOTE_TEMPL, true);
|
||||
if (val < 0)
|
||||
return val;
|
||||
data->temp11[REMOTE_TEMP] = val;
|
||||
@ -1021,7 +1026,7 @@ static int lm90_update_device(struct device *dev)
|
||||
return val;
|
||||
|
||||
val = lm90_read16(client, LM90_REG_REMOTE_TEMPH,
|
||||
LM90_REG_REMOTE_TEMPL);
|
||||
LM90_REG_REMOTE_TEMPL, true);
|
||||
if (val < 0) {
|
||||
lm90_select_remote_channel(data, 0);
|
||||
return val;
|
||||
|