powerpc/pseries: Do not initiate shutdown when system is running on UPS
As per PAPR we have to look for both EPOW sensor value and event modifier to identify the type of event and take appropriate action. In LoPAPR v1.1 section 10.2.2 includes table 136 "EPOW Action Codes": SYSTEM_SHUTDOWN 3 The system must be shut down. An EPOW-aware OS logs the EPOW error log information, then schedules the system to be shut down to begin after an OS defined delay internal (default is 10 minutes.) Then in section 10.3.2.2.8 there is table 146 "Platform Event Log Format, Version 6, EPOW Section", which includes the "EPOW Event Modifier": For EPOW sensor value = 3 0x01 = Normal system shutdown with no additional delay 0x02 = Loss of utility power, system is running on UPS/Battery 0x03 = Loss of system critical functions, system should be shutdown 0x04 = Ambient temperature too high All other values = reserved We have a user space tool (rtas_errd) on LPAR to monitor for EPOW_SHUTDOWN_ON_UPS. Once it gets an event it initiates shutdown after predefined time. It also starts monitoring for any new EPOW events. If it receives "Power restored" event before predefined time it will cancel the shutdown. Otherwise after predefined time it will shutdown the system. Commit79872e3546
("powerpc/pseries: All events of EPOW_SYSTEM_SHUTDOWN must initiate shutdown") changed our handling of the "on UPS/Battery" case, to immediately shutdown the system. This breaks existing setups that rely on the userspace tool to delay shutdown and let the system run on the UPS. Fixes:79872e3546
("powerpc/pseries: All events of EPOW_SYSTEM_SHUTDOWN must initiate shutdown") Cc: stable@vger.kernel.org # v4.0+ Signed-off-by: Vasant Hegde <hegdevasant@linux.vnet.ibm.com> [mpe: Massage change log and add PAPR references] Signed-off-by: Michael Ellerman <mpe@ellerman.id.au> Link: https://lore.kernel.org/r/20200820061844.306460-1-hegdevasant@linux.vnet.ibm.com
This commit is contained in:
parent
17899eaf88
commit
90a9b102ed
@ -184,7 +184,6 @@ static void handle_system_shutdown(char event_modifier)
|
||||
case EPOW_SHUTDOWN_ON_UPS:
|
||||
pr_emerg("Loss of system power detected. System is running on"
|
||||
" UPS/battery. Check RTAS error log for details\n");
|
||||
orderly_poweroff(true);
|
||||
break;
|
||||
|
||||
case EPOW_SHUTDOWN_LOSS_OF_CRITICAL_FUNCTIONS:
|
||||
|
Loading…
Reference in New Issue
Block a user