USB: serial: ti_usb_3410_5052: fix control-message error handling

commit 39712e8bfa8d3aa6ce1e60fc9d62c9b076c17a30 upstream.

Make sure to detect and return an error on zero-length control-message
transfers when reading from the device.

This addresses a potential failure to detect an empty transmit buffer
during close.

Also remove a redundant check for short transfer when sending a command.

Fixes: 1da177e4c3f4 ("Linux-2.6.12-rc2")
Reviewed-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Johan Hovold 2017-01-12 14:56:23 +01:00 committed by Greg Kroah-Hartman
parent b07e930d1f
commit 94bbbfe21b

View File

@ -1556,13 +1556,10 @@ static int ti_command_out_sync(struct ti_device *tdev, __u8 command,
(USB_TYPE_VENDOR | USB_RECIP_DEVICE | USB_DIR_OUT),
value, moduleid, data, size, 1000);
if (status == size)
status = 0;
if (status < 0)
return status;
if (status > 0)
status = -ECOMM;
return status;
return 0;
}
@ -1578,8 +1575,7 @@ static int ti_command_in_sync(struct ti_device *tdev, __u8 command,
if (status == size)
status = 0;
if (status > 0)
else if (status >= 0)
status = -ECOMM;
return status;