p54: fix sequence no. accounting off-by-one error

commit 3b5c5827d1f80ad8ae844a8b1183f59ddb90fe25 upstream.

P54_HDR_FLAG_DATA_OUT_SEQNR is meant to tell the
firmware that "the frame's sequence number has
already been set by the application."

Whereas IEEE80211_TX_CTL_ASSIGN_SEQ is set for
frames which lack a valid sequence number and
either the driver or firmware has to assign one.

Yup, it's the exact opposite!

Signed-off-by: Christian Lamparter <chunkeey@googlemail.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
This commit is contained in:
Christian Lamparter 2011-01-06 23:47:52 +01:00 committed by Greg Kroah-Hartman
parent 0f212b8754
commit 99939b7d2b

View File

@ -618,7 +618,7 @@ static void p54_tx_80211_header(struct p54_common *priv, struct sk_buff *skb,
else
*burst_possible = false;
if (info->flags & IEEE80211_TX_CTL_ASSIGN_SEQ)
if (!(info->flags & IEEE80211_TX_CTL_ASSIGN_SEQ))
*flags |= P54_HDR_FLAG_DATA_OUT_SEQNR;
if (info->flags & IEEE80211_TX_CTL_PSPOLL_RESPONSE)