thermal: core: Send trip crossing notifications at init time if needed

If a trip point is already exceeded by the zone temperature at the
initialization time, no trip crossing notification is send regarding
this even though mitigation should be started then.

Address this by rearranging the code in handle_thermal_trip() to
send a trip crossing notification for trip points already exceeded
by the zone temperature initially which also allows to reduce its
size by using the observation that the initialization and regular
trip crossing on the way up become the same case then.

Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
This commit is contained in:
Rafael J. Wysocki 2024-04-02 21:02:10 +02:00
parent f99c1b87a9
commit 9ad18043fb

View File

@ -364,6 +364,7 @@ static void handle_thermal_trip(struct thermal_zone_device *tz,
struct thermal_trip_desc *td)
{
const struct thermal_trip *trip = &td->trip;
int old_threshold;
if (trip->temperature == THERMAL_TEMP_INVALID)
return;
@ -375,25 +376,11 @@ static void handle_thermal_trip(struct thermal_zone_device *tz,
* is what needs to be compared with the previous zone temperature
* to decide which action to take.
*/
if (tz->last_temperature == THERMAL_TEMP_INVALID) {
/* Initialization. */
td->threshold = trip->temperature;
if (tz->temperature >= td->threshold)
td->threshold -= trip->hysteresis;
} else if (tz->last_temperature < td->threshold) {
/*
* There is no mitigation under way, so it needs to be started
* if the zone temperature exceeds the trip one. The new
* threshold is then set to the low temperature of the trip.
*/
if (tz->temperature >= trip->temperature) {
thermal_notify_tz_trip_up(tz, trip);
thermal_debug_tz_trip_up(tz, trip);
td->threshold = trip->temperature - trip->hysteresis;
} else {
td->threshold = trip->temperature;
}
} else {
old_threshold = td->threshold;
td->threshold = trip->temperature;
if (tz->last_temperature >= old_threshold &&
tz->last_temperature != THERMAL_TEMP_INVALID) {
/*
* Mitigation is under way, so it needs to stop if the zone
* temperature falls below the low temperature of the trip.
@ -402,10 +389,18 @@ static void handle_thermal_trip(struct thermal_zone_device *tz,
if (tz->temperature < trip->temperature - trip->hysteresis) {
thermal_notify_tz_trip_down(tz, trip);
thermal_debug_tz_trip_down(tz, trip);
td->threshold = trip->temperature;
} else {
td->threshold = trip->temperature - trip->hysteresis;
td->threshold -= trip->hysteresis;
}
} else if (tz->temperature >= trip->temperature) {
/*
* There is no mitigation under way, so it needs to be started
* if the zone temperature exceeds the trip one. The new
* threshold is then set to the low temperature of the trip.
*/
thermal_notify_tz_trip_up(tz, trip);
thermal_debug_tz_trip_up(tz, trip);
td->threshold -= trip->hysteresis;
}
if (trip->type == THERMAL_TRIP_CRITICAL || trip->type == THERMAL_TRIP_HOT)