iio: pressure: mprls0025pa fix off-by-one enum
Fix off-by-one error in transfer-function property. The honeywell,transfer-function property takes values between 1-3 so make sure the proper enum gets used. Fixes: 713337d9143ed ("iio: pressure: Honeywell mprls0025pa pressure sensor") Co-developed-by: Andreas Klinger <ak@it-klinger.de> Signed-off-by: Andreas Klinger <ak@it-klinger.de> Signed-off-by: Petre Rodan <petre.rodan@subdimension.ro> Link: https://lore.kernel.org/r/20231229092445.30180-5-petre.rodan@subdimension.ro Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
f088491661
commit
9e65506ca9
@ -323,6 +323,7 @@ static int mpr_probe(struct i2c_client *client)
|
||||
struct iio_dev *indio_dev;
|
||||
struct device *dev = &client->dev;
|
||||
s64 scale, offset;
|
||||
u32 func;
|
||||
|
||||
if (!i2c_check_functionality(client->adapter, I2C_FUNC_SMBUS_READ_BYTE))
|
||||
return dev_err_probe(dev, -EOPNOTSUPP,
|
||||
@ -362,10 +363,11 @@ static int mpr_probe(struct i2c_client *client)
|
||||
return dev_err_probe(dev, ret,
|
||||
"honeywell,pmax-pascal could not be read\n");
|
||||
ret = device_property_read_u32(dev,
|
||||
"honeywell,transfer-function", &data->function);
|
||||
"honeywell,transfer-function", &func);
|
||||
if (ret)
|
||||
return dev_err_probe(dev, ret,
|
||||
"honeywell,transfer-function could not be read\n");
|
||||
data->function = func - 1;
|
||||
if (data->function > MPR_FUNCTION_C)
|
||||
return dev_err_probe(dev, -EINVAL,
|
||||
"honeywell,transfer-function %d invalid\n",
|
||||
|
Loading…