arm64: tegra: Drop unused AHCI clocks on Tegra132

The CML1 and PLL_E clocks are never explicitly used by the AHCI
controller found on Tegra132, so drop them from the corresponding device
tree node.

Signed-off-by: Thierry Reding <treding@nvidia.com>
This commit is contained in:
Thierry Reding 2021-12-07 14:20:25 +01:00
parent 92564257d7
commit 9f27a6c421

View File

@ -635,10 +635,8 @@
<0x0 0x70020000 0x0 0x7000>; /* SATA */
interrupts = <GIC_SPI 23 IRQ_TYPE_LEVEL_HIGH>;
clocks = <&tegra_car TEGRA124_CLK_SATA>,
<&tegra_car TEGRA124_CLK_SATA_OOB>,
<&tegra_car TEGRA124_CLK_CML1>,
<&tegra_car TEGRA124_CLK_PLL_E>;
clock-names = "sata", "sata-oob", "cml1", "pll_e";
<&tegra_car TEGRA124_CLK_SATA_OOB>;
clock-names = "sata", "sata-oob";
resets = <&tegra_car 124>,
<&tegra_car 129>,