usb: dwc3: remove generic PHY calibrate() calls
Calls to USB2 generic PHY calibrate() method has been moved to HCD core, which now successfully handles generic PHYs and their calibration after every HCD reset. This fixes all the timing issues related to PHY calibration done directly from DWC3 driver: incorrect operation after system suspend/resume or USB3.0 detection failure when XHCI-plat driver compiled as separate module. Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com> Tested-by: Anand Moon <linux.amoon@gmail.com> Tested-by: Jochen Sprickerhof <jochen@sprickerhof.de> Acked-by: Felipe Balbi <felipe.balbi@linux.intel.com> Link: https://lore.kernel.org/r/20190829053028.32438-3-m.szyprowski@samsung.com Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
34c7ed72f4
commit
a0a465569b
@ -168,7 +168,6 @@ static void __dwc3_set_mode(struct work_struct *work)
|
||||
otg_set_vbus(dwc->usb2_phy->otg, true);
|
||||
phy_set_mode(dwc->usb2_generic_phy, PHY_MODE_USB_HOST);
|
||||
phy_set_mode(dwc->usb3_generic_phy, PHY_MODE_USB_HOST);
|
||||
phy_calibrate(dwc->usb2_generic_phy);
|
||||
}
|
||||
break;
|
||||
case DWC3_GCTL_PRTCAP_DEVICE:
|
||||
@ -1177,7 +1176,6 @@ static int dwc3_core_init_mode(struct dwc3 *dwc)
|
||||
dev_err(dev, "failed to initialize host\n");
|
||||
return ret;
|
||||
}
|
||||
phy_calibrate(dwc->usb2_generic_phy);
|
||||
break;
|
||||
case USB_DR_MODE_OTG:
|
||||
INIT_WORK(&dwc->drd_work, __dwc3_set_mode);
|
||||
|
Loading…