net: lan966x: Fix the configuration of the pcs
When inserting a SFP that runs at 2.5G, then the Serdes was still configured to run at 1G. Because the config->speed was 0, and then the speed of the serdes was not configured at all, it was using the default value which is 1G. This patch stop calling the serdes function set_speed and allow the serdes to figure out the speed based on the interface type. Fixes: d28d6d2e37d10d ("net: lan966x: add port module support") Signed-off-by: Horatiu Vultur <horatiu.vultur@microchip.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
87f7282e76
commit
b26980ab2a
@ -331,7 +331,6 @@ int lan966x_port_pcs_set(struct lan966x_port *port,
|
||||
struct lan966x *lan966x = port->lan966x;
|
||||
bool inband_aneg = false;
|
||||
bool outband;
|
||||
int err;
|
||||
|
||||
if (config->inband) {
|
||||
if (config->portmode == PHY_INTERFACE_MODE_SGMII ||
|
||||
@ -341,11 +340,6 @@ int lan966x_port_pcs_set(struct lan966x_port *port,
|
||||
config->autoneg)
|
||||
inband_aneg = true; /* Clause-37 in-band-aneg */
|
||||
|
||||
if (config->speed > 0) {
|
||||
err = phy_set_speed(port->serdes, config->speed);
|
||||
if (err)
|
||||
return err;
|
||||
}
|
||||
outband = false;
|
||||
} else {
|
||||
outband = true;
|
||||
|
Loading…