tools/power turbostat: Use standard Energy Unit for SPR Dram RAPL domain
Intel Xeon servers used to use a fixed energy resolution (15.3uj) for
Dram RAPL domain. But on SPR, Dram RAPL domain follows the standard
energy resolution as described in MSR_RAPL_POWER_UNIT.
Remove the SPR rapl_dram_energy_units quirk.
Fixes: e7af1ed3fa
("tools/power turbostat: Support additional CPU model numbers")
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Tested-by: Wang Wendy <wendy.wang@intel.com>
Signed-off-by: Len Brown <len.brown@intel.com>
This commit is contained in:
parent
3ea8e52ec9
commit
b2d433ae63
@ -4567,7 +4567,6 @@ static double rapl_dram_energy_units_probe(int model, double rapl_energy_units)
|
||||
case INTEL_FAM6_SKYLAKE_X: /* SKX */
|
||||
case INTEL_FAM6_XEON_PHI_KNL: /* KNL */
|
||||
case INTEL_FAM6_ICELAKE_X: /* ICX */
|
||||
case INTEL_FAM6_SAPPHIRERAPIDS_X: /* SPR */
|
||||
return (rapl_dram_energy_units = 15.3 / 1000000);
|
||||
default:
|
||||
return (rapl_energy_units);
|
||||
|
Loading…
Reference in New Issue
Block a user